beautypg.com

Device description, 7 electrical data – KROHNE ESK4 Ex II2G Ex iEN User Manual

Page 6

background image

2

DEVICE DESCRIPTION

6

ESK4... ...

www.krohne.com

05/2014 - 4001078702 MA ESK4 Ex II2G AD R02-en

2.7 Electrical data

The connection may only be made using separately certified intrinsically safe isolating amplifiers
or zener barriers with the following maximum values per circuit:

ESK4... ... electrical values

The connector behind the cutout on the ESK4... module cover connects internal intrinsically safe
circuits. Only certified modules of type ESK4 I/O, ESK4 FF or ESK4 PA may be connected. The
additional connector on the ESK 4I/O module connects the optional display as an internal
intrinsically safe circuit.

Type
Signal Output

Terminals

Maximum value per intrinsically safe circuit

U

i

I

i

P

i

C

i

L

i

ESK4 ...

11, 12

30 V

130 mA

1 W

0 nF

10 µH

ESK4-I/O

1, 2, 3 or

4, 5, 6 or

7, 8

30 V

130 mA

1 W

10 nF

0 µH

ESK4-FF / ESK4-PA

D, D-

24 V

380 mA

5.32 W

0 nF

0 µH

FISCO FIELD DEVICE

AD_ESK4_II2G_R02_en_4001078702_PRT.book Page 6 Wednesday, June 25, 2014 7:19 AM