DEVICE DESCRIPTION

2

11

H250 M9

www.krohne.com

10/2012 - 4000646002 MA H250/M9-Ex-II3GD-AD-R06-en

2.8 Surface temperature equipment category II 3 D

For use in areas with flammable dust it should be noted that the indicated maximum surface
temperature of T65°C at an ambient temperature of 60°C / 140°F and a product temperature of
65°C / 149°F is valid without a dust coating. For higher product temperatures the maximum
surface temperature is determined by the product.

2.9

Electrical data

Electrical equipment

Nominal voltage

Nominal current

Limit switch K1 / K2

8 VDC

1...3 mA

Signal output ESK II and ESK2A

24 VDC ± 25%

4...20 mA

with HART communication

ESK3-PA Profibus transmitter

1

9...32 VDC

12 mA

1 Further information and instructions for operation of the ESK3-PA Profibus transmitter are provided in separate sup-

plementary instructions.

AD_H250_M9_II3GD_R06_en_646002_PRT.book Page 11 Wednesday, October 17, 2012 8:03 AM