beautypg.com

Device description – KROHNE H250 M9 ATEX II2G Ex i EN User Manual

Page 8

background image

2

DEVICE DESCRIPTION

8

H250 M9

www.krohne.com

11/2012 - 4000345604 MA H250/M9-Ex-II2G-AD R06 en

Using a heat resistant connecting cable

1 Maximum value of the product temperature for the use of a standard connecting cable. For
higher product temperatures a connecting cable with a temperature resistance of 100°C / 212°F
is required.

HT version - high-temperature version with projecting indicator

The permitted ambient temperature range is indicated on the nameplate.

Ambient temperatures

The minimum product temperature is -40°C / -40°F.

Temperature table in °C

Heating jacket

T

m

1

none

with

HT-version

T

amb

≤ 40

T

amb

≤ 60

DN15, DN25

DN15

-

150

x

-

236

DN50

DN25

-

127

x

-

171

DN80, DN100

DN50, DN80

-

109

x

-

145

Temperature table in °F

Heating jacket

T

m

1

none

with

HT-version

T

amb

≤ 104

T

amb

≤ 140

DN15, DN25

DN15

-

302

x

-

456

DN50

DN25

-

260

x

-

340

DN80, DN100

DN50, DN80

-

228

x

-

293

Version

T

amb.

°

C

°

F

ESK2A, ESK3-PA

-40...+60

-40...+140

SJ3,5-SN / I7S23,5

-40...+60

-40...+140

SC3,5-N0 / SJ3,5-S1N

-25...+60

-13...+140

AD_H250_M9_II2G_R06_en_345604_PRT.book Page 8 Thursday, November 8, 2012 9:42 AM