beautypg.com

Device description, 8 electrical data – KROHNE H250 M40 ATEX II2D Ex t-II2G Ex d EN User Manual

Page 11

background image

DEVICE DESCRIPTION

2

11

H250 M40

www.krohne.com

07/2012 - 4002069601 - MA H250/M40-Ex-II2GD-AD R01

2.8 Electrical data

Electrical equipment

Rated voltage

Nominal current

Limit switches K1 / K2 OC Output

10 - 30 VDC

≤100 mA

Limit switches K1 / K2 NAMUR Output

5- 25 VDC

≤1 / ≥3 mA

Reed contacts R1 / R2

0 - 32 VDC

≤100 mA

Signal output ESK4

14 - 32 VDC

4...20mA with HART

®

communication

Switching output ESK4-T OC output

8 - 32 VDC

1...100 mA

Switching output ESK4-T NAMUR output

8 VDC

≤1 / ≥3 mA

Signal input ESK4-T input

8 - 32 VDC

≤2 mA

ESK4-FF Foundation Fieldbus transmitter

1

9 - 32 VDC

16 mA

ESK4-PA Profibus transmitter

2

9 - 32 VDC

16 mA

1 Further information and instructions for operation of the ESK4-FF transmitter are provided in separate supplementary

instructions.

2 Further information and instructions for operation of the ESK4-PA Profibus transmitter are provided in separate sup-

plementary instructions.

AD_H250_M40_II2GD_R01_en_4002069601_PRT.book Page 11 Friday, July 27, 2012 8:17 AM