beautypg.com

Installation, 7 installation conditions – KROHNE BATCHFLUX 5500 C Quickstart EN User Manual

Page 8

background image

2

INSTALLATION

8

BATCHFLUX 5500 C

www.krohne.com

05/2014 - 4003386301 - QS BATCHFLUX 5500 R03 en

2.7 Installation conditions

2.7.1 Inlet and outlet

2.7.2 Control valve

2.7.3 Pump

∠α > 2°

1. Drain valve (to empty pipeline)

Figure 2-7: Inlet and outlet section

1 ≥ 5 DN
2 ≥ 2 DN
3 Drain valve (to empty pipeline)

3

Figure 2-8: Installation before control valve

Figure 2-9: Installation after pump