Electric models only, Warning (gas models only), Term line voltage – American Dryer Corp. SL50 User Manual
Page 18: High

18
American Dryer Corp.
113403 - 14
Electric Models Only
All electrically heated dryers must be connected to the electric
service shown on the dryer’s data label. The connecting
wires must be properly sized to handle the rated current.
2/8/08
Warning (Gas Models Only)
Dryers built for use with a voltage between 200
and 240 must verify the input voltage during
installation. If the nominal voltage is outside of the
!
TERM
LINE VOLTAGE
50 Hz
60 Hz
HIGH
260
226
283
249
MED
239
208
260
230
LOW
217
189
236
208
medium tolerances shown on
the diagram below, adjust the
autotransformer, located near
the burner assembly. To adjust
the autotransformer wiring,
place the red wire on the
appropriate tap (HIGH, MED,
LOW) of the autotransformer.
For additional wiring details,
refer to the electrical diagram
located on the inside of the control panel.
Electrical Service Specifications
Gas and Steam Models Only
2/8/08
ELECTRICAL SERVICE SPECIFICATIONS
IMPORTANT:
NOTES: A.
B.
C.
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
When fuses are used they must be dual element, time delay, current limiting, class RK1 or
RK5 ONLY. Calculate/determine correct fuse value, by applying either local and/or National
Electrical Codes to listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY. For others,
calculate/verify correct breaker size according to appliance amp draw rating and type
of breaker used.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX. AMP DRAW
CIRCUIT
BREAKER
60 Hz
50 Hz
SL20 Gas
120
1ш
2
8.9
—
15
200
1ш
2
7.7
7.8
15
208
1ш
2
7.6
—
15
220
1ш
2
—
7.4
15
230
1ш
2
—
7.3
15
240
1ш
2
7.2
7.0
15
SL31 Gas
120
1ш
2
10.3
—
15
200
1ш
2
8.7
8.8
15
208
1ш
2
8.4
—
15
220
1ш
2
8.1
8.1
15
230
1ш
2
—
7.4
15
240
1ш
2
7.7
7.0
15
SL31 Steam
120
1ш
2
9.3
—
15
208
1ш
2
—
6.0
15
220
1ш
2
—
5.5
15
230
1ш
2
—
5.4
15
240
1ш
2
5.1
—
15
SL50 Gas
120
1ш
2
15.6
—
20
200
1ш
2
10.5
—
20
208
1ш
2
10.5
—
20
220
1ш
2
10.0
10.7
20
230
1ш
2
—
10.8
20
240
1ш
2
9.7
—
20
SL50 Steam
120
1ш
2
14.4
—
20
200
1ш
2
8.2
—
20
208
1ш
2
8.2
—
20
220
1ш
2
7.8
8.4
20
230
1ш
2
—
8.5
20
240
1ш
2
7.6
—
20
SL75 Gas
120
1ш
2
15.6
—
20
200
1ш
2
10.5
—
20
208
1ш
2
10.5
—
20
220
1ш
2
10.0
10.7
20
230
1ш
2
—
10.8
20
240
1ш
2
9.7
—
20
SL75 Steam
120
1ш
2
14.4
—
20
200
1ш
2
8.2
—
20
208
1ш
2
8.2
—
20
220
1ш
2
7.8
8.4
20
230
1ш
2
—
8.5
20
240
1ш
2
7.6
—
20
ELECTRICAL SERVICE SPECIFICATIONS
IMPORTANT:
NOTES: A.
B.
C.
208 VAC AND 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5
ONLY. Calculate/determine correct fuse value, by applying either local and/or National Electrical
Codes to listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) type ONLY. For others, calculate/verify correct
breaker size according to appliance amp draw rating and type of breaker used.
Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
OVEN
kW
APPROX.
AMP DRAW
CIRCUIT
BREAKER
60 Hz
50 Hz
SL20
200
1ш
2
5.6
32.7
32.7
45
208
1ш
2
4.1
24.2
—
35
208
1ш
2
6.1
34.0
—
45
220
1ш
2
6.8
35.6
—
45
230
1ш
2
5.0
—
26.4
35
230
1ш
2
7.4
—
36.8
50
240
1ш
2
5.4
27.1
—
35
240
1ш
2
8.1
38.4
38.4
50
208
3ш
3
6.5
22.7
—
30
240
3ш
3
7.5
22.6
—
30
380
3ш
4
6.8
—
15.0
20
400
3ш
4
7.5
—
15.5
20
416
3ш
4
8.1
—
15.8
20
SL31
200
1ш
2
12.5
68.4
67.7
90
208
1ш
2
7.9
43.8
—
60
208
1ш
2
13.5
70.7
—
90
230
1ш
2
8.3
—
41.3
60
230
1ш
2
12.4
—
59.1
80
240
1ш
2
9.0
42.7
—
60
240
1ш
2
13.5
61.5
—
80
208
3ш
3
13.5
43.3
—
60
220
3ш
3
11.3
35.3
—
50
230
3ш
3
12.4
—
36.5
50
240
3ш
3
13.5
37.7
—
50
380
3ш
4
11.3
22.8
22.6
40
400
3ш
4
12.4
—
23.1
40
416
3ш
4
13.5
—
23.7
40
SL50
200
1ш
2
14.8
82.1
—
110
208
1ш
2
16.0
85.1
—
110
220
1ш
2
13.4
68.8
69.4
90
230
1ш
2
14.7
—
72.3
100
240
1ш
2
16.0
74.2
75.1
100
200
3ш
3
14.8
—
51.0
70
208
3ш
3
16.0
52.6
—
70
220
3ш
3
13.4
43.0
43.6
60
230
3ш
3
14.7
—
45.3
60
240
3ш
3
16.0
46.0
—
60
380
3ш
4
13.4
28.0
28.6
40
400
3ш
4
14.8
—
29.8
40
416
3ш
4
16.0
—
30.7
40
SL50 Dual Voltage 480 / 120
120
1ш
2
0.0
13.2
—
15
480
3ш
3
16.0
19.2
—
25
SL50 Dual Voltage 480 / 240
240
1ш
2
0.0
6.5
—
15
480
3ш
3
16.0
19.2
—
25
SL50 Dual Voltage 600 / 120
120
1ш
2
0.0
13.2
—
15
600
3ш
3
16.0
15.4
—
20
SL50 Dual Voltage 600 / 240
240
1ш
2
0.0
6.5
—
15
600
3ш
3
16.0
15.4
—
20
SL75
200
1ш
2
20.3
109.8
—
150
208
1ш
2
22.0
113.9
—
150
220
1ш
2
18.5
91.7
92.3
125
230
1ш
2
20.3
—
96.3
125
240
1ш
2
22.0
99.2
—
125
208
3ш
3
22.0
69.2
—
90
220
3ш
3
18.5
56.2
56.8
80
230
3ш
3
20.3
—
59.1
80
240
3ш
3
22.0
60.4
—
80
380
3ш
4
18.5
35.6
—
45
380
3ш
4
18.5
—
36.2
50
400
3ш
4
20.3
—
37.8
50
416
3ш
4
22.0
—
39.1
50