INSTALLATION INSTRUCTIONS

12

Figure 10

NOTE: It is now necessary to turn on the power in order to to change the Operating
Mode (if applicable), program any changes desired to the operator’s other settings, check
for proper operation, and finalize any adjustments to include the limit settings.
Before
doing so, ensure that all mounting hardware are installed and properly tightened, that all
electrical connections are per local code requirements, and that proper wiring practices have
been followed. Also, double-check that all ropes have been removed from the door and
that the doorway is clear.

P

C

B 11

269

5 R

E

V

B

T

S

L

K

OP

EN

C25

PB1

PB2

PB3

U5

STOP

CLOSE

OPEN

C1

R84

R2

R3

D12

CO

M

CL

OS

E

ST

O

P

NO

RE

V

NC

RE

V

PH

OT

O

RADIO

24V

R56

R55

R54

P

C

B

11

2695

RE

V

B

T

S

L

K

OPEN

RM1

RM2

RM3

VCC

COM

P7

C25

R94

R87

R38

PB1

PB2

PB3

R5

R25

STOP

CLOSE

OPEN

C24

U1

D8

U4

C1

1

R30

R26

R29

C3

C1

C8

R95

R2

R3

D2

R65

C10

D3

C9

D12

R57

COM

CLO

S

E

STOP

NO

REV

NC

RE

V

MOTOR

CONTROL

BOARD

MOTOR

CONTROL

BOARD

Single 3 Button Station

Multiple 3 Button Station

Figure 11

C

D

O

M

CB

2005

c.

p

. ALLS

TAR

C

O

R

P

R8

R24

TB1

P5

R93

U5

R4

C21

D1

EXTERNAL INTERLOCK

PH

O

T

O

COM

SI

NG

L

E

ILO

C

K

24 V

A

C

COM

MOTOR

CONTROL

BOARD

Single Button and External Interlock Wiring

Figure 12

Note: When adding an External Interlock
remove the factory installed jumper from
the connection terminals.

TURNING ON THE POWER TO THE OPERATOR

This manual is related to the following products: