Warning, Stopping the generator – WEN 56475 4750W Electric Start User Manual
Page 25

22
SOME NOTES ABOUT POWER CORDS
Long or thin cords can drain the power provided to an electrical device by the generator. When
using such cords, allow for a slightly higher rated wattage requirement by the electrical device.
See Figure 18 for recommended cords based on the power requirement of the electrical device.
Device Requirements
Max. Cord Length (ft) by Wire Gauge
Amps
Watts (120V)
Watts (240 V)
#8 wire #10 wire #12 wire #14 wire #16 wire
2.5
300
600
NR
1000
600
375
250
5
600
1200
NR
500
300
200
125
7.5
900
1800
NR
350
200
125
100
10
1200
2400
NR
250
150
100
50
15
1800
3600
NR
150
100
65
NR
20
2400
4800
175
125
75
50
NR
25
3000
6000
150
100
60
NR
NR
30
3600
7200
125
65
NR
NR
NR
40
4800
9600
90
NR
NR
NR
NR
*NR= not recommended
Figure 18- Maximum Extension Cord Lengths by Power Requirement
STOPPING THE GENERATOR
To stop the generator:
1. Turn off all electrical devices prior to unplugging them from the generator. Unplugging
running devices can cause damage to the generator.
2. Turn the engine switch to the “OFF” position.
3. Turn the fuel valve to the “OFF” (horizontal) position.
WARNING:
Allow the generator to cool for several minutes before touching
areas that become hot during use.
CAUTION: Allowing gas to sit in the generator tank for long periods of time without use can
make it difficult to start the generator in the future. Never store generator for extended
periods of time with fuel in the tank.