WEN 56400 4050 Watt User Manual
Page 15

To start your generator, perform the following steps:
1. No electrical devices should be connected to the generator during starting. Devices can
make it difficult for the engine to start.
2. Check that the generator is properly grounded (see “Ground the Generator”).
3. Check the oil and fuel levels.
4. Turn the fuel valve to the “on” position (see figure 5).
5. Move the choke lever to the “closed” position (see figure 6).
6. Set the engine switch to the “on” position.
7. Pull on the recoil starter handle slowly until a slight resistance is felt. Then pull quickly to
start the engine. Return cord gently into the machine. Never allow the cord to snap back.
8. If engine fails to start, repeat step 7. NOTE: After repeated failed attempts to start the
engine, please consult the troubleshooting guide before attempting again. If problems
persist please call (800) 232-1195 M-F 8-5 CST.
9. Once the engine has started, slowly return the choke lever all the way to the “open”
position.
10. Allow the generator to run for several minutes before attempting to connect any electrical
devices. This allows the generator to stabilize its speed and temperature.
Figure 5- Fuel Valve in the “on” position
Figure 6- Pull choke out for closed position.
Push `in for open position.
12