Problem cause solution, Troubleshooting service – WEN 2276 6 Gallon Horizontal Air Compressor User Manual
Page 16

#2276OPERATOR’SMANUAL
16
®
Problem
Cause
Solution
AirCompressor
willnotstart
ThermalOverload
Allowtocoolandpushtheresetbutton
locatedintheCrankcaseclosetotheAir
Filter.
Blownfuseorcircuitbreakertripped. Replaceorresetfuse/circuitbreaker.
Looseelectricalconnections
Checkwiringconnections
Lowpressure
RestrictedAirFilter
ReplaceAirFilter
DefectiveCheckValve
ReplaceCheckValve
AirleakinSafetyValve
Checkvalvebypullingonring.Ifcondition
persists,replacevalve
Safetyvalve
releasing
DefectivePressureSwitch
Replacepressureswitch
Oildischargein
AirCompressor
ToomuchoilinCrankcase
DrainCrankcaseandrefilltoproperlevelon
OilSightGlass
Compressoroverheated
Reduceairpressureregulation.
RestrictedOilBreatherCap
CleanorreplaceOilBreatherCap.
If trouble persists please call our customer service
1-800-232-1195, M–F 8–5 (CST)
1. Mechanicaland/orelectricaltoolserviceistobeperformedonlybyprofessionalqualifiedrepair
personnel.Serviceperformedbyunqualifiedpersonnelmayresultinariskofinjury.
2. Whenservicingatool,useonlyidenticalreplacementparts.Useofunauthorizedpartsorfailureto
followmaintenanceinstructionsmaycreateariskofelectricalshockorinjury.
NOTE: Ifanypartsaredamagedormissing,donotattempttopluginthepowercordandturnthe
switchonuntilthedamagedormissingpartsareobtainedandareinstalledcorrectly.
TROUBLESHOOTING
SERVICE