Seed Hawk
®
Manual Calibration Guide
4
Pressing the SETUP soft key
brings up this screen. Turning
decimal shift off will reduce the
accuracy from two decimal
places to one decimal place.
Meter cal is the number of
pulses per revolution. This
number is dependent on the
encoder inside the hydraulic
motor and should not be
changed from the default
value of 60.
Measure and record the
weight of the empty
calibration bucket. Remove
the plate on the bottom of the
meter and place the
calibration bucket under the
meter as shown. Turn the
diverter valve to the lower air
stream position for calibration
(return to proper position after
calibration is complete).
Calibration Bucket
Weight: