2014 LOUP III & VIPER PRO™ HYDRAULIC DRIVE CALIBRATION GUIDE

2

The

Calibration Numbers chart (pg. 1) is a starting point ONLY. Fine tuning of the calibration number is

necessary to achieve desired accuracy.

Use the Rate Check Procedure

(pg. 34) to further verify calibration number accuracy.

If desired product is not present in the Calibration Numbers Chart, a static calibration is needed. See Static
Calibration Procedure relating to your control system (Loup III or Seed Hawk Viper Pro™).

IMPORTANT! This booklet pertains to hydraulic drive systems only.

The metering rollers will turn during the

calibration procedure. Keep away from moving

components when performing a catch test using

the remote tank console.

Be aware of bystanders and alert anyone

around the air cart when performing the

calibration process.