Frequency designation dc / ac inverters, Ac / ac frequency converters, Series it – Schaefer Series IT User Manual
Page 4
www.schaeferpower.de
Frequency Designation
DC / AC Inverters
with 1-phase output from 200VA to 15kVA
AC output
DC input
Inverter Transformer
AC / AC Frequency Converters
with 1-phase output from 500VA to 15kVA
Inverters
Inverters
AC output
AC input
Inverter Transformer
Series IT
Switch mode inverter and transformer
Eurocassette / approx. 9 kg
Wall mount / approx. 11 kg
Eurocassette / approx. 11 - 13 kg
Wall mount / approx. 13 - 15 kg
42TE
6U
16
6.5 mm
220 mm
360 mm
168 mm
42TE
6U
226 mm
220 mm
360 mm
229 mm
Eurocassette / approx. 16 - 18 kg
Wall mount / approx. 19 - 21 kg
Eurocassette / approx. 18 - 24 kg
Wall mount / approx. 21 - 27 kg
56TE
6U
306 mm
280 mm
360 mm
309 mm
19“ Plug-in module / approx. 46 - 50 kg
Wall mount / approx. 54 - 58 kg
19“ Plug-in module / approx. 32 kg
Wall mount / approx. 36 kg
19"
6U
460 mm
500 mm
600 mm
310 mm
19"
6U
360 mm
500 mm
400 mm
310 mm
Wall mount version
W
H
D
Trans -
former
H
W
D
Weight
in kg
in mm
T1
T2
T3
T4
390
450
450
500
240
280
280
320
233
253
283
280
33
50
66
110
Trans -
former
H
W
D
Weight
in kg
in mm
T1
335
230
210
33
Size A
Size B
Size C
Size D
Size E
Size F
Transformers refer to 50/60 Hz.
Other frequencies or tropical insulation may
change size and weight.
Transformers refer to 50/60 Hz.
Other frequencies or tropical insulation may
change size and weight.
56TE
6U
306 mm
280 mm
360 mm
309 mm
Standing version
W
H
D
Size T1 - T4
Size T1
19“, 3U Plug-in module
3HE
19"
362mm
19“, 3U high packages:
available for series IT16xx up to IT36xx.
= incl. temperature controlled fans
Optional
Standard
Optional
Standard
Optional
Standard
Optional
Standard
Optional
Standard
Optional
Standard
Optional
Size L
.1
.2
.3
.4
.41
.5
.51
.6
.61
.7
.8
40 - 400 Hz adjustable / programmable
45 - 65 Hz adjustable / programmable
any fixed frequency between 40 - 400 Hz
400 Hz
synchronized with 400 Hz mains
50 Hz
synchronized with 50 Hz mains
60 Hz
synchronized with 60 Hz mains
50/60 Hz switchable
800 Hz
Input VDC
Cooling
Output
VAC
20 –32
VDC
Output
kVA
Size
40 – 64
VDC
50 –80
VDC
Output
kVA
Size
80 – 160
VDC
Output
kVA
Size
160 – 320
VDC
340 –400
VDC
340 – 640
1)
VDC
450 –800
1)
VDC
Output
kVA
Size
IT 1626
0.2
A
IT 1636
IT 3636
IT 4836
IT 5636
IT 5736
IT 1646
IT 3646
IT 4846
IT 5646
IT 5746
0.4
0.5
1.2
2
3
A
B
D
E
E
IT 1656
IT 3656
IT 3856
IT 4856
IT 5656
IT 5756
0.5
1
1.2
2
3
5
A
B
C
D
E
F + T1
IT 1676
IT 3676
IT 3876
IT 4876
IT 5676
IT 5776
IT 5876
IT 5976
IT 1686 Z
IT 3686 Z
IT 3886 Z
IT 4886 Z
IT 5686 Z
IT 5786 Z
IT 5886 Z
IT 5986 Z
IT 3676 G
IT 3876 G
IT 4876 G
IT 5676 G
IT 5776 G
IT 5876 G
IT 5976 G
IT 3876 K
IT 4876 K
IT 5676 K
IT 5776 K
IT 5876 K
IT 5976 K
0.5
1
1.6
2.5
2.5
5
8
10
15
A
B
C
D
D
F + T1
F + T2
F + T3
F + T4
115
IT 1628
0.2
A
IT 1638
IT 3638
IT 4838
IT 5638
IT 5738
IT 1648
IT 3648
IT 4848
IT 5648
IT 5748
0.4
0.5
1.2
2
3
A
B
D
E
E
IT 1658
IT 3658
IT 3858
IT 4858
IT 5658
IT 5758
0.5
1
1.2
2
3
5
A
B
C
D
E
F + T1
IT 1678
IT 3678
IT 3878
IT 4878
IT 5678
IT 5778
IT 5878
IT 5978
IT 1688 Z
IT 3688 Z
IT 3888 Z
IT 4888 Z
IT 5688 Z
IT 5788 Z
IT 5888 Z
IT 5988 Z
IT 3678 G
IT 3878 G
IT 4878 G
IT 5678 G
IT 5778 G
IT 5878 G
IT 5978 G
IT 3878 K
IT 4878 K
IT 5678 K
IT 5778 K
IT 5878 K
IT 5978 K
0.5
1
1.6
2.5
2.5
5
8
10
15
A
B
C
D
D
F + T1
F + T2
F + T3
F + T4
230
= natural convection = incl. temperature controlled fans
1)
standard version: wall mount
IT 3636
IT 3646
0.5
B
IT 3656
1
B
IT 3676
IT 3686 Z
IT 3676 G
1
B
IT 4836
IT 4846
1.2
D
IT 4856
2
D
IT 4876
IT 4886 Z
2.5
D
IT 5636
IT 5646
2
E
IT 5656
3
E
IT 5676
IT 5686 Z
IT 5676 G
IT 5676 K
5
F + T1
IT 5876
IT 5886 Z
IT 5876 G
IT 5876 K
10
F + T3
IT 1638
IT 1648
0.4
A
IT 1658
0.5
A
IT 1678
IT 1688 Z
0.5
A
IT 3858
1.2
C
IT 3878
IT 3888 Z
IT 3878 G
IT 3878 K
1.6
C
IT 4878 G
IT 4878 K
2.5
D
IT 5738
IT 5748
3
E
IT 5758
5
F + T1
IT 5778
IT 5788 Z
IT 5778 G
IT 5778 K
8
F + T2
IT 5978
IT 5988 Z
IT 5978 G
IT 5978 K
15
F + T4
Input VAC
1-Phase
Output
kVA
Size
Input VAC
1-Phase
Input VAC
3-Phase
Output
kVA
Size
Cooling
Output
VAC
115
± 20 %
230
+ 15 %
– 20 %
3x200
+ 15 %
– 20 %
3x400
+ 15 %
– 20 %
3x480
+ 10 %
– 15 %
IT 1666
IT 3666
IT 3866
IT 4866
IT 5666
IT 5766
0.5
1
1.2
2
3
5
A
B
C
D
E
F + T1
IT 1686
IT 3686
IT 3886
IT 4886
IT 5686
IT 5786
IT 1666 V
IT 3666 V
IT 3866 V
IT 4866 V
IT 5666 V
IT 5766 V
IT 3686 V
IT 3886 V
IT 4886 V
IT 5686 V
IT 5786 V
IT 5886 V
IT 5986 V
IT 3896 V
IT 4896 V
IT 5696 V
IT 5796 V
IT 5896 V
IT 5996 V
0.5
1
1.6
2.5
5
8
12
15
A
B
C
D
F + T1
F + T2
F + T3
F + T4
115
IT 1668
IT 3668
IT 3868
IT 4868
IT 5668
IT 5768
0.5
1
1.2
2
3
5
A
B
C
D
E
F + T1
IT 1688
IT 3688
IT 3888
IT 4888
IT 5688
IT 5788
IT 1668 V
IT 3668 V
IT 3868 V
IT 4868 V
IT 5668 V
IT 5768 V
IT 3688 V
IT 3888 V
IT 4888 V
IT 5688 V
IT 5788 V
IT 5888 V
IT 5988 V
IT 3898 V
IT 4898 V
IT 5698 V
IT 5798 V
IT 5898 V
IT 5998 V
0.5
1
1.6
2.5
5
8
12
15
A
B
C
D
F + T1
F + T2
F + T3
F + T4
230
IT 3666
1
B
IT 3686
IT 3666 V
IT 3686 V
1
B
IT 4866
2
D
IT 4886
IT 4866 V
IT 4886 V
IT 4896 V
2.5
D
IT 5766
5
F + T1
IT 5786
IT 5766 V
IT 5786 V
IT 5796 V
8
F + T2
IT 5986 V
IT 5996 V
15
F + T4
IT 3668
1
B
IT 3688
IT 3668 V
IT 3688 V
1
B
IT 4868
2
D
IT 4888
IT 4868 V
IT 4888 V
IT 4898 V
2.5
D
IT 5768
5
F + T1
IT 5788
IT 5768 V
IT 5788 V
IT 5798 V
8
F + T2
IT 5988 V
IT 5998 V
15
F + T4
= natural convection
= incl. temperature controlled fans