Schaefer Series IT User Manual
Page 3
www.schaeferpower.de
1 or 3-Phase Output from 200VA to 45kVA, switchmode
Inverters
Series IT - Inverters with 1-phase output
from 200 VA to 15 kVA
Page 89
DC/AC Inverters
is a combination of a switch mode Inverter and a Transformer at the output. The
transformer provides the isolation between input and output and transforms
the voltage to the required level.
AC output
DC input
Inverter Transformer
AC/AC Frequency Converters
is a combination of a switch mode Inverter with a rectifier at the input and
a Transformer at the output. The transformer provides the isolation between
input and output and transforms the voltage to the required level.
AC output
AC input
Inverter Transformer
For lower input voltages the CI version is more compact than the IT version.
Series CI - Inverters with 1-phase output
from 400 VA to 3.5 kVA
Page 91
DC/AC Inverters
is a combination of a switch mode Converter and Inverter. The converter
provides the isolation between input and output and transforms the voltage to
the level needed by the inverter for supplying the specified AC output voltage.
AC output
DC input
Converter Inverter
AC/AC Frequency Converters
is a combination of a switch mode Converter and Inverter. The converter
provides the isolation between input and output and transforms the voltage to
the level needed by the inverter for supplying the specified AC output voltage.
AC output
AC input
Converter Inverter
Series IV - Inverters with 3-phase output
from 600VA to 45 kVA
Page 93
DC/AC or AC/AC
AC output
DC or
AC input
3 x Inverter
3-phase
3 x Transformer
is a combination of 3 individual switch mode inverters with output transformers
synchronized for a symmetrical 3-phase output. The transformers provide the
isolation between input and output and transform the voltages to the required
levels.
Series SS
from 800 VA to 10 kVA
Page 97
Static Switches
The Static Switch has two inputs for load supply, a priority and a non-priority
input, and synchronizes the frequency of one supply to the other. Typically, but
not exclusively, supplied by Mains & an Inverter, there are 3 modes of operation:
1. Service mode Mains - mains is selected as the load provider.
2. Service mode Inverter - inverter is selected as the load provider.
3. Automated function with priority selection.
AC output
AC supply 1
AC supply 2
static switch
1-phase
Series U
from 1 to 2.5 kVA
Page 99
UPS Systems with Static Switch
provides uninterrupted AC power to a critical load by connecting the load to
AC supply 1 which can be the inverter output or to AC supply 2 which can
be the mains. Series U does not include the batteries. The batteries can be
specified and both, batteries and charger can be added to the system.
=
AC mains
Static Switch
Bypass Switch
AC output
(Load)
Inverter
Battery
Connectors
for Series CI, IT, IV & SS
Page 132
Mechanics
Series CI
Series IT
Series IV
Series SS
Series U
Eurocassette
H15 & high currrent connector for I >50 A
H15 and F24H7
--
H15 and F48
--
Wall mount or 19“ unit
Terminals
Terminals
Terminals
Terminals
Terminals