SANDPIPER MPS03 User Manual
Handi-pump model mps03, Service & operating manual, Operating instructions

mps03dl3sm-rev1110
Model MPS03 Page 1
MARATHON
®
• Warren Rupp, Inc. • A Unit of IDEX Corporation • 800 N. Main St., Mansfield, Ohio 44902 USA
Telephone (419) 524-8388 • Fax (419) 522-7867 • www.warrenrupp.com
OPERATING INSTRUCTIONS
THE PUMP: This pump is a totally enclosed, submersible dewatering unit. It is
powered
by a 1/3 HP, 12 volt DC 30 AMP motor. Battery clips on the power cord allow
easy connection to any 12 volt vehicle battery.
SWITCHING: The on-off switch is located on the power cord.
CONNECTING TO BATTERY: When connecting the clips to a battery, arcing is
eliminated by keeping the on-off switch in the “off” position. Connect the red battery
clamp to the positive (+) battery terminal. Connect the black battery clamp to ground:
preferably on the vehicle’s engine to a solid, metallic, stationary point. The connection
should be at least 18 inches (480mm) from the battery.
IMPORTANT SAFETY
INFORMATION
Turn off before connecting battery
clamps to battery. Arcing could result.
DANGER
IMPORTANT
Read these safety warnings
and instructions in this
manual completely, before
installation and start-up of the pump. It
is the responsibility of the purchaser to
retain this manual for reference. Failure to
comply with the recommendations stated
in this manual will damage the pump, and
void factory warranty.
HOSE: Since the pump develops relatively low pressure, it is recommended that
non-collapsible hose be used for maximum pumping rates.
HOISTING & LOWERING: Attach a line to the metal handle on the top of the
pump for hoisting or lowering the unit.
Do not use power cable for handling unit.
TO OPERATE: Lower unit into liquid to be pumped and activate switch. Pump
can be run for a few minutes without liquid, however,
do not run completely dry for
extended periods. Damage to shaft seal may result.
RUNNING TIME: This unit draws about 30 amperes and can be operated
about 1hour on a fully charged 55 AMP-hour battery and still permit starting of
vehicle under normal conditions. Caution should be used when running time
exceeds 30 or 40 minutes without engine running to recharge battery, particularly
in cold weather when battery efficiency is lowered. Battery size (AMP-hour rating)
and the use of other accessories such as lights and radios, etc., must be taken into
consideration for practical running periods without engine running.
OVERLOAD PROTECTION is provided by means of a 40 amp automatic reset
circuit breaker, located under top cover.
1. Make sure the vehicle and the
pump are not in contact during
connection.
2. Do not use power cable for handling
unit.
3. Do not run completely dry for
extended periods. Damage to shaft
seal may result.
DANGER
DANGER: Not for use with
fluids that have a flash point
below 100° F (38° C) [examples:
gasoline, alcohol.] Sparking could result
in death.
Handi-Pump
Model MPS03
SERVICE & OPERATING MANUAL
Original Instructions