beautypg.com

Check valve drawing – SANDPIPER M1F Metallic User Manual

Page 27

background image

M1fmdl1sm-rev0214

Model M1F Metallic Page 25

Check Valve Drawing

CHECK VALVE SERVICING

Before servicing the check valve

components, first shut off the suction

line and then the discharge line to the

pump. Next, shut off the compressed

air supply, bleed air pressure from the

pump, and disconnect the air supply

line from the pump. Drain any remaining

fluid from the pump. The pump can now

be removed for service.

To access the check valve

components, remove the manifold

(item 20 or item 19 not shown). Use a

1

/

2

" wrench or socket to remove

the fasteners. Once the manifold is

removed, the check valve components

can be seen.

Inspect the check balls (items 2) for

wear, abrasion, or cuts on the spherical

surface. The check valve seats (item

29) should be inspected for cuts,

abrasive wear, or embedded material

on the surfaces of both the external

and internal chambers. The spherical

surface of the check balls must seat

flush to the surface of the check valve

seats for the pump to operate to

peak efficiency. Replace any worn or

damaged parts as necessary.

Re-assemble the check valve

components. The seat should fit into

the counter bore of the outer chamber.

The pump can now be reassembled,

reconnected and returned to operation.

METALLIC SEATS

Two o-rings (item 22) are required

for metallic seats.

with Non-Metallic

Seats

with Metallic Seats

20

9

2

29

22

29

22

30