beautypg.com

Models msb2 and msb2-b, Ball valve type 3 mine/construction duty, Service and operating manual – SANDPIPER MSB2-B User Manual

Page 3

background image

msb2dl3sm-REV0614

Model MSB2 Page 1

PRINCIPLE OF PUMP OPERATION

This ball valve pump is powered by compressed air and is a 1:1 pressure ratio

design. It alternately pressurizes the inner side of one diaphragm chamber, while

simultaneously exhausting the other inner chamber. This causes the diaphragms,

which are connected by a common rod, to move endwise. Air pressure is applied over

the entire surface of the diaphragm, while liquid is discharged from the opposite side.

The diaphragm operates under a balanced condition during the discharge stroke,

which allows the unit to be operated at discharge heads over 200 feet (61 meters)

of water head.

Since the diaphragms are connected by a common rod, secured by plates to the

center of the diaphragms, one diaphragm performs the discharge stroke, while the

other is pulled to perform the suction stroke in the opposite chamber.

For maximum diaphragm life, keep the pump as close to the liquid being pumped

as possible. Positive suction head in excess of 10 feet of liquid (3.048 meters) may

require a back pressure regulating device. This will maximize diaphragm life.

Alternate pressuring and exhausting of the diaphragm chamber is performed by

means of an externally mounted, pilot operated, four-way spool type air distribution

valve. When the spool shifts to one end of the valve body, inlet air pressure is applied

to one diaphragm chamber and the other diaphragm chamber exhausts. When the

spool shifts to the opposite end of the valve body, the porting of chambers is reversed.

The air distribution valve spool is moved by an internal pilot valve which alternately

pressurizes one side of the air distribution valve spool, while exhausting the other

side. The pilot valve is shifted at each end of the diaphragm stroke by the diaphragm

plate coming in contact with the end of the pilot spool. This pushes it into position for

shifting of the air distribution valve.

The chambers are manifolded together with a suction and discharge flap-type

check valve for each chamber, maintaining flow in one direction through the pump.

INSTALLATION & START-UP

Locate the pump as close to the product being pumped as possible, keeping

suction line length and number of fittings to a minimum. Do not reduce line size.

For installations of rigid piping, short flexible sections of hose should be installed

between pump and piping. This reduces vibration and strain to the piping system.

A Warren Rupp Tranquilizer

®

surge suppressor is recommended to further reduce

pulsation in flow.

This pump was tested at the factory prior to shipment and is ready for operation.

It is completely self-priming from a dry start for suction lifts of 10 feet (3.05 meters) or

less. For suction lifts exceeding 20 feet of liquid, fill the chambers with liquid prior to

priming.

AIR SUPPLY

Air supply pressures cannot exceed 125 psi (8.61 bar). Connect the pump air inlet

to an air supply of sufficient capacity and pressure required for desired performance.

When the air line is solid piping, use a short length of flexible hose [not less than

3/4" (19mm) in diameter] between pump and piping to eliminate strain to pipes.

SERVICE AND OPERATING MANUAL

Models MSB2 and MSB2-B

Ball Valve

Type 3

Mine/Construction Duty

II 2GD T5

This manual is related to the following products: