Non-metallic ball valve, Design level 1 air operated double diaphragm pump, Materials – SANDPIPER S10 User Manual
Page 3

s10nmdl1sm-rev0614
Models S10 Non-Metallic Page 1
Santoprene
®
Injection molded thermoplastic elastomer with no fabric layer. Long mechanical flex
275°F
-40°F
50° to 212°F
life. Excellent abrasion resistance.
135°C
-40°C
10°C to 100°C
PTFE Chemically inert, virtually impervious. Very few chemicals are known to react chemically with
Teflon: molten alkali metals, turbulent liquid or gaseous fluorine and a few fluoro-chemicals such as
220°F
-35°F
50°F to 212°F
chlorine trifluoride or oxygen difluoride which readily liberate free fluorine at elevated temperatures.
104°C
-37°C
10°C to 100°C
PVDF
250°F
0°F
121°C
-18°C
Polypropylene
180°F
32°F
82°C
0°C
Quality System
ISO 9001 Certified
Environmental
Management System
ISO 14001 Certified
Materials
Maximum*
Minimum*
Optimum**
*Definite reduction in service life.
**Minimal reduction in service life at ends of range.
Operating Temperatures
For specific applications, always consult “Chemical Resistance Chart” Technical Bulletin
SANDPIPER
®
pumps are designed to be powered only by compressed air.
INTAKE/DISCHARGE PIPE SIZE
CAPACITY
0 to 23 US gallons per minute
(0 to 87 liters per minute)
AIR VALVE
No-lube, no-stall
design
SOLIDS-HANDLING
Up to .15 in. (4mm)
HEADS UP TO
100 psi or 231 ft. of water
(7 bar or 70 meters)
DISPLACEMENT/STROKE
.026 US gallon / .098 liter
CAUTION! Operating temperature limitations are as follows:
Polyurethane
210°F
99°C
-40°F
-40°C
-40°F to 210°F
-40°C to 99°C
1" ANSI Flange
Nylon
180°F
82°C
32°F
0°C
FKM (Fluorocarbon): Shows good resistance to a wide range of oils and solvents; especially all aliphatic,
aromatic and halogenated hydrocarbons, acids, animal and vegetable oils. Hot water or hot aqueous
solutions (over 70°F) will attack FKM.
350°F
177°C
-40°F
-40°C
CAUTION: Nonmetallic pumps and plastic components are not UV stabilized. Ultraviolet radiation can damage these parts and negatively affect material properties.
Do not expose to UV light for extended periods of time.
S10
Non-Metallic
Ball Valve
Design Level 1
Air Operated
Double Diaphragm Pump
ENGINEERING, PERFORMANCE
& CONSTRUCTION DATA