Maintenance wiring diagram, 230v electrical schematic, 115v electrical schematic – RIKON Power Tools 10-325 User Manual
Page 16: 115v lamp electrical schematic
![background image](/manuals/364162/16/background.png)
16
BEFORE CLEANING OR CARRYING OUT MAINTENANCE WORK, DISCONNECT
THE MACHINE FROM THE POWER SOURCE (WALL SOCKET). NEVER USE WATER OR
OTHER LIQUIDS TO CLEAN THE MACHINE. USE A BRUSH. REGULAR MAINTENANCE OF THE
MACHINE WILL PREVENT UNNECESSARY PROBLEMS.
Keep the table clean to ensure accurate cutting.
Keep the outside of the machine clean to ensure accurate operation of all moving parts and prevent
excessive wear.
Keep the ventilation slots of the motor clean to prevent it from overheating.
Keep the inside (near the saw blade, etc.) clean to prevent accumulation of dust.
This machine must be grounded.
Replacement of the power supply cable should only be done by a qualified electrician.
As received from the factory, your bandsaw is ready to run at 115V operation. It can be switch to
230V according to below schematic.
Maintenance
Wiring Diagram
WARNING
!
Caution!
Plug
Cord
Switch
230V Electrical Schematic
Plug
Motor
Cord
Switch
115V Electrical Schematic
Plug
115V Lamp Electrical Schematic
Switch
Lamp
0
0
Motor
Blue
Brown
Black
White
Blue
Brown
Black
White