LT Security PTZKB636 User Manual
Page 9
User Manual of System Keyboard
- 16 / 21 -
3.1.2 Working mode of keyboard system:
This working mode is mainly used in direct-control decoders and intelligent
Hi Speed Domes. To enter this mode, change No. 8 terminal in ID to “ON”.
Baud rate selection setting: the baud rate of the keyboard can be set by
changing terminals 5 and 6 in ID. Baud rate is selected to assure that the
keyboard has the same data transmission rate as the control equipment.
Control protocol: under the same baud rate, decoders and intelligence High
Speed Domes in different control protocols by changing No. 1, 2, 3 and 4 in
ID.
No.
1 2 3 4
Control protocol
1
1 0 0 0
PELCO-D
2
0 1 0 0
PELCO-P
3
1 1 0 0
ALEC
Position of
code position
5 6
Baud rate
Position of
code position
5 6
Baud rate
1 0
1200
1 1
4800
0 1
2400
0 0
9600
User Manual of System Keyboard
- 17 / 21 -
3.2 Schematic drawing of connection between keyboard and matrix
mainframe
The keyboard joint-box is connected to the communication interface with a
plain shielded two-core twisted-pair cable, 1200 meters long at most.
DC 12V power line
:white—DC12V;black —GND.