Self-calibration – Johnson Level & Tool Mfg. 1880-4800 User Manual

Page 9

background image

©2013 Johnson Level & Tool - Rev. 1

9

6. Self-Calibration

To Calibrate this unit:

Quick Level Calibration

1. Turn the digital level on.
2. Hold the digital level against a wall making sure the level

bubble is centered in the vial.

3. While keeping the digital level in the level position push and

hold the CAL button in for 3 seconds.

4. “CAL” will flash on the LCD indicating the digital level is in the

calibration process.

5. If the digital level is not kept stable or if the digital level is

tipped to far forward or backward, “ERRO” will appear on the
LCD. Push the Calibration Button one time to exit calibration
mode and repeat the procedure.

6. If the calibration procedure is successful, the LCD will display

“rdy”. The calibration procedure is completed and the digital
level will exit the calibration procedure automatically.

Quick Plumb Calibration

1. Turn the digital level on.
2. Hold the digital level against a wall making sure the plumb

bubble is centered in the vial.

3. While keeping the digital level in the plumb position push and

hold the CAL button in for 3 seconds.

IMPORTANT: It is the responsibility of the user to verify the
calibration of the instrument before each use.