Note:
If after several attempts of starting the exhaust
begins to emit white smoke, move the speed
control lever to the STOP position and pull the
starting cable out slowly 5 times. Repeat the
starting procedure, Chapter 4.2.1.

4.2.3. Recoil start for versions with

electric starter (till -6°C)

The recoil starter at engines with electric start is
an emergency starting device without decom-
pression automatic.
Therefore, attention has to be paid to the exact
starting procedure as mentioned below.

– Prepare the engine for starting;

see Chapter 4.2.1.

– Pull out the handle with the cord slowly until

compression resistance is clearly felt; Fig. 12.

– Continue to pull slowly but with greater force

until the resistance becomes noticeably less
(compression overcome).

– Now let the cord run back - the engine is in

the correct starting position.

In this way the engine can be accelerated
through about one and a half revolutions with
the starting cord, to overcome compression re-
sistance and achieved the required momentum
for starting.

– Support equipment with the foot if it is too

light in weight or liable to tip over.

– Take hold of the handle with both hands;

Fig. 13.

– Pull the starting cord up forcefully and at an

increasing speed (but do not jerk it) - the en-
gine should then start; Fig. 14.

Note:
In the case of engines with automatic electrical
shutdown system
(see next chapter), first
actuate the starter switch from position 0 to
position I, then perform a recoil start within the
following 12 seconds. If the engine does not run
after 12 seconds, this means that the electrical
system blocks the fuel supply to the injection
pump.
In this case, the engine cannot be started.
As a solution, turn the starter key back to posi-
tion 0
, then turn it to position I again. Now, start
the engine within the following 12 seconds.

4.2.4. Electric starter

– For starting preparations, see Chapter 4.2.1.

15

– Insert the key to its stop and turn it to

position I.

– Battery charge telltale „2“ and oil pressure

warning „3“ must light up.

– Turn start key to position II.

– As soon as the engine runs, release the start

key. It must return to position I by itself and
remain in this position during operation.