Orion-3a pneumatic pressure controller – Condec Orion-3A User Manual
Page 2
© CONDEC 2001 • All rights reserved • Printed in the United States of America • Specifications subject to change without notice
March 2001
65370
Page 2
2.80
1.75
PRESSURE
VALVE
#10-32 UNF-2B
(2) PLACES
FITTING LOCATION
INLET PORT 1/8-27 NPT
MATING FITTING, PN 59731
1.82
VENT VALVE
FITTING LOCATION
VENT PORT
1/8-27 NPT
MATING FITTING, PN 59731
Seri
alNo.
Patent No.4.698.998
M o d e l N o . O rio n
3 A
P re s s u re : 0 - 0 0 0 0
p s i
P ro o f
P re s s u re :1 5
0 0
p s i
1
0
TEST PORT#2
MS33649-04 THREAD
6.90
RETAINER PLATE ASSY, PN 56424
REMOVE AT TIME OF PANEL MOUNTING
TEST PORT#1
1/8-27 NPT
MATING FITTING, PN 59731
VERNIER
2.70
STOP WASHER
LOCK NUT
KNOB INSERT
KNOB
SETSCREW #6-32
5.80
1.75
1.450
2.900
1.450
1.350
(2) PLACES
Ø .213
(2) PLACES
RECOMMENDED HOLE PATTERN FOR ORION 3A
ORION-3A Pneumatic Pressure Controller
Part #55287, Patent No. 4.698.998
INSTALLATION:
The valve is factory adjusted.
Panel or bracket mounting:
1. Turn the two outside knobs clockwise.
2. Remove all (three) knobs.
3. Install controller into recommended
hole pattern with two
10-32 x 1/2" lg. screws.
4. Install knobs, align set
screws with both
dimples on knob inserts
and shaft.