Burcam 150143 HEAT SHRINK SPLICING KIT 4 TUBES User Manual
Installation instructions, Heat shrink splicing kit
To avoid risk of electric shock, remove the power
cord from the electrical outlet.
Step 1 : Strip approx. 1/4” (6mm) of wire insulation
from both end of wires to connect. Clean wires
about 3” from ends and put tube over one end.
Step 2 : Insert one wire end into wire connector
and crimp it.
Step 3 : Insert the second wire end into wire con-
nector and crimp it.
Step 4 : Set the connector in the middle of the
tube.
Step 5 : Shrinking can be accomplished through
the use of a thermo gun or flame torch with a utility
head or other broad flame. Begin at one end of
tubing. Keep tubing out of direct contact with
flame. Keep flame moving back and forth.
Step 6 : Progress toward other end as tubing
shrinks and wrinkles
disappear. Keep the flame moving. A small amount
of glue should be
visible around the ends of the tube.
Step 7 : Let tube to cool before pump installation.
Step 8 : Put together all splinced wires and use
electrical tape to cover the complete heat shrink
from beginning to end.
2190 Boul. Dagenais West
TEL: 514.337.4415
LAVAL (QUEBEC)
FAX: 514.337.4029
CANADA
H7L 5X9 [email protected]
INSTALLATION
INSTRUCTIONS
MODEL
150143
150152
HEAT SHRINK
SPLICING KIT
Please read these
instructions
carefully. Failure
to comply to
instructions and
designed
operation of
this system,
may void the
warranty.
2001 BUR-CAM Printed in Canada 140502
1
2
3
4
5
6