Repair parts – Burcam 300403 EMERGENCY BACK UP PUMP 12V User Manual
Page 5
5
FOR INFORMATION TEL: 514.337.4415 FAX: 514.337.4029
5
REPAIR PARTS
Fix the control box to the battery box.
Plug the float switch, pump and charger to the appropriate connector as
per picture 5. Test pump operation by filling the sump with water while the
main pump is unplugged. If the pump operates properly, plug the charger
into the GFCI protected outlet to keep the battery charged.
Protect electrical cord from sharp objects, hot surfaces, oil and chemicals.
Avoid kinking the cord and replace damaged components immediately.
STEP 12
STEP 13
STEP 14
The control box contains a multi-colored indicator lights.
1- The green charged light indicates a full charge.
2- The red battery low light indicates a low voltage.
3- The yellow charging light indicates a charge function in process.
4- The red reversed light indicates a reverse connection on the batterie cables.
5- The alarm selector can be put in on or off position as per your choice. If the alarm
turns on, the red alarm light will turn on.
6- To test the pump operation, push the pump test button.
7- To stop the alarm, if in on position, push the reset button.
Note that if activated, the alarm will turn on as soon as the pump turns on. This will warn you that
the pump turned on due to a power failure or a primary pump failure.
REF M
ODEL
D
ESCRIPTION
1
310660
Upper box cover
2
310661
Lower box base
3
310672
Alternative handles (2)
4
310667
Screws (4)
5
310673
PVC ties (4)
6
310670
Black belt
7
310666
Float
8
310659
Pump
9
310676
Impeller & lock washer
10 310677
Pump O -Ring
11 310663
Volute
12 310662
Suction screen
13 52259
Reducer 1” to 1 1/4”
14 52258
90° Elbow
15 350353
1 1/4” check valve
16 310665
AC Adaptor
17 310664
Control box
18 310668
Big head screws (4)
19 310671
Battery cable clamp
Model 300403H 2007
1
2
3
4
5
6
17
7
15
18
19
14
16
13
8
9
10
11
12
Picture #5