Installation steps, Step 1 step 2 step 3 step 4 – Burcam 300402 SUMP BUDDY SUBM. BACK UP MUNICIPAL WATER SUMP PUMP User Manual
Page 3
FOR INFORMATION TEL: 514.337.4415 FAX: 514.337.4029
3
APPLICATION
This pump is designed to be connected to
any existing conventional type sump pump
system, as an extra sump pump protection.
CAPACITY AT 60 PSI
(municipal water pressure):
5’ 581 US GPH
Friction loss
10’ 317 US GPH
in pipe
15’ 158 US GPH
not included
FEATURES
Extra protection during power outage or in the
event of failure of conventional sump pump.
Easy to connect to existing conventional sump
pump discharge line.
Automatic control valve activate the SUMP
BUDDY.
No electricity required.
No battery required.
INSTALLATION STEPS
(see diagram on page 5)
We recommend that you install your SUMP BUDDY in a location where there is adequate
room for servicing at a later date. Discharge line should be made from ABS or PVC 1 1/4” ,
1 1/2” or 2” pipe.
We do not recommend to install flexible drain kit due to friction loss. Head capacity and/or
discharge flow will be reduce in a large proportion.
Use teflon tape on all connections.
Keep suction screen and ejector clean.
Check regularly your SUMP BUDDY to ensure its proper operation. Remember that solids or
debris in water should be removed from the sump pit.
Remove electrical power of your existing conventional sump pump and verify that this sump
pump is equipped with a check valve at pump discharge. If not, add a check valve before
continuing your installation. The sump pump check valve should be located at the primary
pump discharge and installed below the “Y” fitting.
Locate your SUMP BUDDY in an ideal position and cut the existing discharge line to install
the T or Y fitting. Cut the desired length of pipe to connect the discharge line from the check
valve of the SUMP BUDDY to the T or Y fitting.
Run this discharge line with fittings to adjust your SUMP BUDDY in vertical position.
We recommend that the distance between the bottom of the SUMP BUDDY and the bottom
of the sump pit be approximately 2”.
STEP 1
STEP 2
STEP 3
STEP 4
Check valve required
as per step 2.
350353 1 ½”