Safety instructions, Ab c e d – Burcam 300722 1/2HP 115V EFFLUENT PUMP VERTICAL SWITCH 20 User Manual
Page 2
Submersible effluent pump installation
Desired length of 1 1/2” or 1 1/4” of ABS/DWV pipe to link up the pump to the drain line.
1 only 1 1/4” check valve (350353) (Note that this 1 1/4” check valve may also be use
with a 1 1/2” pipe).
18” x 25” sump basin.
1 1/4”-1 1/2” stainless steel clamps (750886).
ABS cement.
2
Tools
Screwdrivers, hacksaw to cut pipe, knife to assist in pipe cutting, round file to smooth pipe
ends, pipe wrench, adjustable wrench to tighten fittings.
Check with your local electrical and plumbing codes to ensure you comply with the regulations.
These codes have been designed with your safety in mind.
Be sure you comply with them.
We recommend that a separate circuit be lead from the home electrical distribution panel properly
protected with a fuse or a circuit breaker. We also recommend that a ground fault circuit be used.
Consult a licensed electrician for all wiring.
The ground terminal on the three prong plugs should never be removed. They are supplied and
designed for your protection.
Never make adjustments to any electrical appliance or product with the power connected. Do not
only unscrew the fuse or trip the breaker, remove the power plug from the receptacle.
Assuming that you have a sump pit located in your basement floor... Your sump pit must be con-
structed from concrete, brick, tile or more recently a sump basin made from plastic and/or fiber-
glass. The minimum size of your sump pit MUST be 18” in diameter and no less than 25” deep.
When pit is ready, proceed to next step.
SAFETY INSTRUCTIONS:
This fine pump that you have just purchased is designed from the latest in material and
workmanship. Before installation and operation, we recommend the following procedures:
Material required for submersible effluent pump application
NOTICE
This unit is not designed for applications
involving salt water or brine.
Use with salt water or brine will void
warranty.
A
B
C
E
D