Repair parts, Sewage pump application, Step 3 – Burcam 400401T SEWAGE PUMP 1/2HP 115V User Manual
Page 5: Step 2, Step 4, Step 5, Step 6, Step 7, Step 8, Step 9
![background image](/manuals/361764/5/background.png)
REPAIR PARTS
STEP 3
Cement 2” adaptor to
pipe
STEP 2
Install sewage basin
STEP 4
Drill a 1/4” hole
SEWAGE PUMP APPLICATION
STEP 5
Install discharge
pipe and lower
pump in centre of
basin
STEP 6
Set gaz tight
cover, discharge
and vent pipes
STEP 7
Install check
valve
STEP 8
Connect to receptacle
STEP 9
Fill with water and
test operation
STEP 10
Secure cover and
make vent connection
400401T
5
Repair parts may be ordered from your authorized point of sale or from
BUR-CAM PUMPS
FOR INFORMATION TEL: 514.337.4415 FAX: 514.337.4029
REF
#ITEMS
DESCRIPTIONS
1
400353
Power cable
2
300487
Handle
3
400355
Stator
4
400356
Motor upper plate
5
400357
Motor cover
6
400358
Seal plate
7
400359
Motor base plate
8
400360
Pump casing
9
400361
Impeller
10
400362
Bottom plate
11
400363
Oil seal
12
400364
Mechanical seal
13
350335
Upper bearing
14 506031
Lower bearing
15
400367
Rotor & shaft
REF
#ITEMS
DESCRIPTIONS
16
400368
Capacitor
17
400369
Motor casing
18
400370
Top gasket
19
400371
Seal plate "O" ring
20
400374
Oil seal bushing
21
450446
Vertical switch
22
450453
Mechanical switch
23
400375
"O" ring motor base (2)
24
450700
Cable & screw of handle (4)
25
450701
Bolts housing &cover (8)
26
450702
Screws (4)
27
450703
Plate base screws (3)
28
300485
Discharge adaptor
29
450704
Capacitor clamp
30
450705
Long bolt (4)
5
2
16
4
15
14
7
12
6
20
9
10
8
21
17
13
3
11
1
22
21
24
18
25
23
30
28
26
27
29
19