Repair parts, Sewage pump application, Step 3 – Burcam 400416T HEAVY DUTY GRINDER PUMP 3/4HP 115V User Manual
Page 5: Step 2, Step 4, Step 5, Step 6, Step 7, Step 8, Step 9
REPAIR PARTS
STEP 3
Cement 2” adaptor to
pipe
STEP 2
Install sewage basin
STEP 4
Drill a 1/4” hole
SEWAGE PUMP APPLICATION
STEP 5
Install discharge
pipe and lower
pump in centre of
basin
STEP 6
Set gaz tight
cover, discharge
and vent pipes
STEP 7
Install check
valve
STEP 8
Connect to receptacle
STEP 9
Fill with water and
test operation
STEP 10
Secure cover and
make vent connection
5
Repair parts may be ordered from your authorized point of sale or from
BUR-CAM PUMPS
#
REF
DESCRIPTION
1
450331
Strainer
2
450332
Oil cover “O” ring
3
400447G Grinder impeller
4
450333
Pump body
5
400450
Oil cover
6
400449
Oil seal
7
400448
Mechanical seal
8
506032
Lower bearing
9
450335
Motor casing
10
450336
Motor housing
“O” rings(2)
11
400453
Rotor shaft
12
400454
Stator
13
506032
Upper bearing
14
450338
Inside cover
15
400451
Capacitor
16
450340
Head cover
17
450341
Inside cover “O” ring
#
REF
DESCRIPTION
18
400446
Power cable
19
300487
Handle
20
310312
Handle bolts (2)
21
450702
Screws (4)
22
450020
Long bolts (4)
23
450021
Head cover nuts
24
450022
Head cover
spring ring (4)
25
450023
Impeller nut
26
450026
Plate capacitor
screws (2)
27
450704
Capacitor clamp
28
310310
Capacitor screw clamp
29
450025
Capacitor plate
30
450024
Impeller snap ring
31
450453
Mechanical switch
32
450706
Centrifugal switch
18
16
15
29
17
14
13
11
9
8
7
21
5
6
1
12
28
10
2
31
20
29
24
23
22
27
28
19
3
4
26
25
32