Trouble shooting guide checklist, Trouble probable cause action – Burcam 700506 CENTRIFUGAL PUMP 1.5HP 230V User Manual
Page 8
FOR INFORMATION TEL: 514.337.4415 FAX: 514.337.4029
TROUBLE SHOOTING GUIDE CHECKLIST
NEVER MAKE ADJUSTMENTS TO ANY ELECTRICAL APPLIANCE OR PRODUCT WITH THE POWER
CONNECTED. DON’T JUST UNSCREW THE FUSE OR TRIP THE BREAKER, REMOVE THE POWER
FROM THE RECEPTACLE.
Switch is off position
Blown fuse
Tripped breaker
Defective motor
Pump not primed
Leaky suction line
Foot valve plugged
Water level below foot valve
Suction lift to great
Improper voltage
Water level below foot valve
Excessive friction in pipe
Improper voltage
Leaky suction line
Gaz in water
Turn switch to on position
Replace
Reset
Replace
Prime with clean water
Check pipe and pipe connections
Clean
Check foot valve level
Water level lower than lift capacity
Check voltage
Check foot valve level
Too small or dirty pipe
Check voltage
Check pipe and pipe connections
Check and consult factory
TROUBLE PROBABLE CAUSE ACTION
Motor does not
run.
Motor runs but
no water is
delivered.
Pump does not
deliver to full
capacity.
Air spurts from
fawcets.
TO THE END CONSUMER
If you have any problems with the product, before advising the store, where you’ve
purchased the pump, please contact us at 514 337-4415 , and ask for our sales department,
and they will be pleased to help you with any questions you might have, concerning your
installation.
8