Step 1, Installation steps – Burcam 506721 CONVERTIBLE C.I. JET PUMP 3/4HP 115/230V User Manual
Page 3
![background image](/manuals/361744/3/background.png)
3
APPLICATIONS
• This pump is designed for shallow well installation
for water level up to 25 feet, with injector screwed
on pump body; or for deep well installation for water
level up to 80 feet, with 2 pipes and injector down in
the well.
• CAPACITY AT 30 PSI
:
SHALLOW WELL
DEEP WELL
1/2 HP 3/4 HP
1/2 HP 3/4 HP
5’ 585 660
10’ 510 525
30’ 520 550
15’ 440 450
40’ 420 450
20’ 330 350
50’ 330 350
25’ 220 250
80’ 150
75
US GPH
US GPH
FEATURES
• High performance brass impeller.
• Industrial motor totally enclosed, fan cooled.
• Full time connected run capacitor, to eliminate
starting wear vs regular motor.
• Thermal and overload protection.
• Built for a continuous use.
• 1/2 HP, 115 VCA, 60 Hz, 8A
, (
17A
at start ).
• 3/4 HP, 115 VCA, 60 Hz, 9A
, (
19A
at start ).
Friction loss in pipe not included.
INSTALLATION STEPS
We recommend that you install your pump in a clean and dry location where there is adequate room
for servicing at a later date. Protection from freezing temperatures and good ventilation should be
considered as well, to provide the pump an environment for long life. Locating the pump as close as
possible to the water source will reduce friction losses encountered in the suction pipe.
Friction losses in the suction pipe must be taken into consideration when the horizontal offset is greater
than 50 feet. The suction pipes should be increased from 1” to 1 1/4”. This will reduce friction losses and
allow the pump to give maximum performance.
A new well should be checked to determine that it is free from sand. Sand will damage the seal and the
impeller. Have your well driller clean the well before your installation.
Never run the pump dry. Damage to the seal may occur. Fill pump body and suction pipe with water
before turning on the power.
THE RUN OF HORIZONTAL PIPE FROM THE TOP OF YOUR WELL INTO THE HOUSE,
WHERE YOUR PUMP WILL BE LOCATED, MUST BE INSTALLED IN A TRENCH, BELOW THE
FROST LEVEL OF YOUR AREA.
STEP 1
For installation where the water level is between
0 to 25 feet (0
to 7.5 m) deep from the pump location, your injector as been pre-
installed in manufacture with the venturi 506308.1. It is a shallow
well application mode. Only one (1) pipe is required to pump from
this level. The injector is fixed directly to the pump body (see on page 4).
However, if the pumping level is between 25 to 80 feet (7.5 to 24 m)
deep from the pump location, you will need to remove the injector
from the pump body, unscrew the nozzle venturi pre-installed and
replace it by the enclosed nozzle/venturi 506308.2. This is a deep
well application mode. The injector will be installed into the well with
two (2) pipes fixed to the pump body (see on page 5).
For deep well application mode, 25’ to 80’.
For shallow well application mode, 0’ to 25’.