beautypg.com

1 speaker connection – Nexo 45N Monitor User Manual

Page 8

background image

Page 8/26

45N12

G

ENERAL

S

ET

-

UP

I

NSTRUCTIONS

2 45N12

G

ENERAL

S

ET

-

UP

I

NSTRUCTIONS

2.1 Speaker

connection

NEXO 45°N-12 are connected with Speakon NL4FC plugs (not supplied). A wiring diagram is printed on
the connection panel located on the back of each cabinet. The 4 pins of the 2 Speakon sockets
identified in / out are connected in parallel within the enclosure.

Either connector can be used to connect amplifier or to link to an additional 45N12 cabinet.

2.1.1 45°N-12 Connector Panel

Connectors are wired as follows:

2.1.2 Configuring 45N12 for Passive or Active Mode

IMPORTANT

45N12 are factory configured in active mode

In order to change active or passive configuration:

- remove the TORX screws that hold the rear/bottom metal panel;

- remove the rear/bottom metal panel to access passive network WAGO connectors.

In Passive Mode, WAGO connector should be inserted in “Passive In”, and speakers WAGO
connectors should be inserted in connector “Passive Out”.

In Active Mode, WAGO Connector should be directly connected to speakers via speakers WAGO
connectors (passive filter is then bypassed).

Speakon

Connector

Passive

Mode

Active

Mode

1(-)

Ö

Not Connected

45N12 LF (-)

1(+)

Ö

Not Connected

45N12 LF (+)

2(-)

Ö

45N12 (-)

45N12 HF (-)

2(+)

Ö

45N12 (+)

45N12 HF (+)