Preparing the outlet cylinder – MAHLE RTI RRC750-SP1 User Manual
Page 4

Page 3
PREPARING THE OUTLET CYLINDER
1. Connect one end of a Yellow Hose to the Liquid Port of the Outlet Cylinder.
2. Connect other end of the Yellow Hose to a Deep Vacuum Pump.
3. Close Vapor Valve.
4. Open Liquid Valve and valve on Yellow Hose.
5. Connect Vacuum Pump to power source.
6. Draw a vacuum on the Outlet Cylinder for one hour.
7. Close Outlet Cylinder Liquid Valve and valve on Yellow hose.
8. Disconnect Yellow Hose from Vacuum Pump and connect to rear access port of the 750-SP1.