beautypg.com

Safety precautions – MAHLE RTI RRC770A User Manual

Page 5

background image

Page 2

SAFETY PRECAUTIONS

!

Recover, Recycle, and Charge only the refrigerant for which the machine is configured.

!

Wear safety glasses and protective gloves. Refrigerant has a very low boiling point and
can cause frostbite.

!

Follow the RRC770 operating procedures sequentially to avoid prematurely
disconnecting hoses or opening valves which may release refrigerant to the
atmosphere.

!

Do not expose the RRC770 to moisture or operate in wet areas.

!

Use the RRC770 in locations with mechanical ventilation that provides at least four air
changes per hour.

!

Hoses used with the RRC770 must have shutoff devices within 12 inches of the
connection point to the system being serviced to minimize the introduction of Non-
condensable Gas (Air) into the RRC770 and the release of refrigerant when being
disconnected.

!

Disconnect power before performing any maintenance or service on the RRC770.

!

Avoid using an extension cord with the RRC770. If necessary, use a good condition,
UL listed, 3-wire grounded, #14 AWG extension cord of the shortest possible length.
Connect the RRC770 to a properly protected, grounded receptacle. Do not over load
the circuit.

!

Do not allow the RRC770 to remain unattended in the Charge Mode with power On.
The Internal Cylinder Heater will be energized creating a high pressure condition.

NEVER TURN THE CYLINDER UP-SIDE-DOWN.

DO NOT CONNECT THE RRC770 TO THE LIQUID SIDE OF ANY
A/C SYSTEM WITH A CAPACITY GREATER THAN 4 LBS.

REFRIGERANT IN A/C SYSTEMS HAVING LARGER CAPACITIES
MUST BE RECOVERED FROM THE VAPOR SIDE ONLY.

NEVER CONNECT THE RRC770 TO THE LIQUID PORT OF A
CYLINDER OF REFRIGERANT TO FILL THE RRC770 INTERNAL
CYLINDER.

FAILURE TO FOLLOW THE ABOVE MAY CAUSE THE RRC770
COMPRESSOR TO FAIL AND VOID THE WARRANTY.