Scheduled maintenance, Filter maintenance – MAHLE RTI TC670E User Manual
Page 15

RTI Technologies, Inc.
Page 14
SCHEDULED MAINTENANCE
WEEKLY ...
Check the oil level in the Compressor at least once a week.
The Oil Level Sight Tube is visible through a cut-out in the left side of the black Compressor Cover
at the bottom of the TC670E.
The oil level should be visible in the small nylon tube.
If oil is not visible or is above the middle of the cut-out call Technical Support at
800-468-2321.
MONTHLY ...
Clean the Condenser to maintain high efficiency performance of the TC670E. Disconnect power and
remove the Compressor Compartment Cover and blow compressed air through the cooling fins of
the Condenser to remove any debris.
Do not bend the fins on the Condenser coil. Air flow will be restricted and cause damage to the
TC670E. Replace the Compressor Compartment Cover before applying power to the TC670E.
FILTER MAINTENANCE
Two Combo Filters are installed on the rear of the TC670E.
The hour meter on the top control panel of the TC670E accumulates hours as refrigerant is being
purified by the two filters during the recycle process.
Monitor the accumulated hours and change both filters at each twenty-five hour increment. It is good
practice to replace both filters at least annually.
Call Technical Support (800-468-2321) for your nearest distributor of filters.
Short Combo Filter P/N:
026-80069-00
Long Combo Filter P/N:
026-80077-00
Remove and re-attach the foam on the short filter during replacement. Check for leaks immediately
after changing filters during the first recover/recycle procedure.