5

6 SHOWER ONLY OUTLET CONNECTIONS

(Fig.C)

Connect shower outlet pipe (1) to valve body outlet (2).

Connect a Pipe Elbow (3) (not included) to end of outlet

pipe.
7 TUB ONLY OUTLET CONNECTIONS

(Fig.D)

Connect tub outlet pipe (1) to valve body outlet (2). Route

the outlet pipe to tub outlet hole and connect a Pipe Elbow

with nipple (3) (not included) to end of the pipe.
8 PRESSURE TESTING VALVE (Fig.E)

Use an iron pipe plug (not included) on shower outlet or

tub outlet. Remove Screws (1) and Plasterguard (2) from

Valve Body (3). Perform pressure test. Look for leaks from

the outlets.

WARNING: Pressure testing is not to exceed 250 PSI.

Make sure pressure is balanced between hot and cold

inlets.

WARNING: Differential pressure of hot and cold inlets must

not exceed 100 PSI.

CAUTION: Slowly remove pipe plugs from tub and

shower outlets to relieve pressure.

1

3

2

C

1

2

3

D

1

2

3

E