7 HANDLE FLANGE ATTACHMENT

Place Plastic Ring (7A) and Flange (7B) over Valve Body (7C) covering the Valve Body
Washers (7D). Secure by threading Plastic Nut (7E) onto the Valve Body (7C).

9 SPOUT BODY ATTACHMENT

Insert Lift Rod (9A) into hole at the back of Spout Body (9B). Apply plumber’s putty
into putty groove in bottom of Seal Ring (9D). Place Washer (9C) and Seal Ring (9D)
against the bottom of Spout Base (9E). Place Spout Base (9E) against the bottom of
Spout Body (9B). With Spout Body (9B) facing forward, carefully install the Lift Rod
(9A) and Shank (9F) through the center hole of sink (9G).

10 SECURING SPOUT BODY

From underneath sink, secure Spout Body (10A) by placing Metal Washer (10B) and
threading Long Nut (

7

/

16

Hex.) (10C) onto Mounting Post (10D). Make sure that the

bumps on Metal Washer (10B) are facing up. Make sure Lift Rod (10E) moves freely.
Firmly hand tighten Long Nut (10C). Secure Long Nut (10C) not to exceed a

1

/

4

turn.

Caution: Do not over tighten!

8 HANDLE INSTALLATION

With valves in “CLOSE” position, place Handle Hub (8A) onto Valve Stem (8B), connect
Lever (8C) onto Handle Hub (8A).Attach and secure with Screw (8D). Attach Decorative
Button (8E).