CAUTION: Maintenance
DISASSEMBLY
1. Replacement parts may be available at the store where you purchased
your faucet.
2. When replacement parts are not available, please write or call Price
Pfi ster Consumer Service.
3. Always turn off water and relieve pressure before working on your
faucet.
NOTE: Trim Care
Cleaning Instructions:
For all Handles and decorative fi nishes, use only a soft damp
cloth to clean and shine. Use of polish, detergents, abrasive
cleaners, organic solvents or acid may cause damage. Use of
other than a soft damp cloth will nullify our warranty!
Special Trim:
Trim products which contain Porcelain or other similar
substance are not acceptable for public areas or Commercial
use. Installation of Said Trim is at Users Risk!
1–800–PFAUCET (1–800–732–8238)
For Toll-Free Pfaucet information call
1–800–PFAUCET (1–800–732–8238)
or visit www.pricepfi ster.com
• Installation Support
• Care and Warranty Information
22 HANDLE REMOVAL
Turn off water before proceeding! With valves in closed position, detach Decorative
Button (22A), unscrew Fastener (22B), and remove Handle Hub (22C) from Valve
Stem (22D).
23 CARTRIDGE REMOVAL
Turn off water supplies and relieve pressure before working on your faucet (see
step 2). Remove Handle (See step 22) Remove the Dome Cap (23A) by unscrewing
it in a counterclockwise direction. Using an adjustable wrench, unscrew the Retainer
Ring (23B). Carefully remove the Cartridge (23C) by pulling it straight up and out.
Inspect Cartridge (23C) for debris or damage. Clean or replace the Cartridge (23C).
Reassemble faucet by reversing steps.
24 PULL-OUT HOSE REMOVAL
To remove the quick connect attachment: Push up on Quick Connector (24A). Holding
grey Plastic Colette (24B) in place, pull downward on Quick Connector (24A) until Tube
(24C) is free.