beautypg.com

English, Maintenance and care – Pfister GT26-4YPK User Manual

Page 6

background image

ENGLISH

ENGLISH

21

24

22

23

CAUTION: Maintenance

DISASSEMBLY
1.

Replacement parts may be available at the store where you purchased
your faucet.

2.

When replacement parts are not available, please write or call Price
Pfister Consumer Service.

3.

Always turn off water and relieve pressure before working on your
faucet.

NOTE: Trim Care

Cleaning Instructions:
For all Handles and decorative finishes, use only a soft damp
cloth to clean and shine. Use of polish, detergents, abrasive
cleaners, organic solvents or acid may cause damage. Use of
other than a soft damp cloth will nullify our warranty!
Special Trim:

Trim products which contain Porcelain or other similar
substance are not acceptable for public areas or Commercial
use. Installation of Said Trim is at Users Risk!

1–800–PFAUCET (1–800–732–8238)

For Toll-Free Pfaucet information call
1–800–PFAUCET (1–800–732–8238)
or visit www.pricepfister.com

• Installation Support
• Care and Warranty Information

MAINTENANCE AND CARE

21 FLUSHING & AERATOR CLEANING

After installation is complete, remove Aerator Housing (21A). Turn Valve
(21B) on and allow both hot and cold water to run for at least one minute each.
While water is running, check for leaks. To clean the aerator, disassemble Aerator
Housing (21A) by separating the Aerator Shell (21C), Basket (21D), and Washer
(21E). Once parts have been cleaned, reassemble by reversing steps.

22 HANDLE REMOVAL

Using a 3/32” Allen wrench, loosen Set Screw (22A) and remove Handle

(22B).

23 CARTRIDGE REMOVAL
Turn off water supplies and relieve pressure before working on your
faucet.
Remove handle (see figure 22). Using pliers, unscrew the retainer
ring (23A). Carefully remove the Cartridge (23B) by pulling it straight up and
out. Reassemble valve by reversing steps.

24 HOSE REMOVAL

To remove hose attachments from Diverter Tee (24F), push on Connection
Fittings (24A & 24B). Holding Plastic Collet (24C) in place, pull out on Connection
Fittings (24A & 24B) until Hoses (24D & 24E) are free.