Frequency 60HZ single phase
WARNING: Even low voltage
can cause irreparable damage
or death! Exercise extreme
caution while operating or
servicing this equipment.
Cord Apparatus
Voltage A/C AMPS
Incandescent lamp (75 watt max)
125
13
Fluorescent lamp
125
0.3
LED lamp
125
13
Single outlet
125
13
Dual receptacle box
125
20
Triple tap
125
15
IMPORTANT
Read this manual carefully before installing, operating or
servicing this equipment.
A
13 1/4”
B
12 5/8”
C
8”
D
2 1/2”
E
9 3/8”
F
1 3/4”
Dimensions
Personal injury and/or equipment damage may
result if proper safety precautions are not
observed.
• Ensure that only a qualified electrician
installs/services this equipment.
• Ensure that power supply voltage does not
exceed maximum voltage rating of reel.
• Ensure that reel is properly installed before
connecting to power supply.
• All cord reels with flying leads must be hard
wired to ensure proper function.
• Ensure that all electrical power is removed
from reel before servicing.
• A high-tension spring assembly is
contained within the reel. Exercise extreme
caution.
• Check for frayed and/or broken wires before
each use. Pull electrical cord from reel by
grasping the electrical cord itself, not the
work device.
• If an electrical malfunction should occur,
remove power from reel immediately.
• Ensure that reel, electrical cord, and
equipment being serviced are properly
grounded. Use an ohmmeter to check
ground continuity.
• If reel ceases to unwind or rewind, remove
power immediately. Do not pull or jerk on
electrical cord!
• Treat and respect the reel as any other piece
of machinery, observing all common safety
practices.
Mounting
CAUTION: Unless reel was specified differ-
ently when ordering, maximum installation
height is 16 feet. Do not exceed this distance.
Ensure that only a qualified electrician installs/
services this equipment. Installation of GFCI
cord reels should be performed by a qualified
and licensed professional in accordance with
building codes and applicable NEC standards.
1. Unpack and inspect reel for damage.
Turn by hand to check for smooth opera-
tion. Check for completeness.
2. Configure reel for top, side or bottom-
wind (bottom-wind for constant tension
reels only) electrical cord dispensing by
removing bolts (1), securing guide arm
bracket (2). Determine new guide arm
location and remove corresponding bolts.
Position guide arm bracket to reel and
replace bolts.
3. Position reel on floor, wall, or ceiling.
Secure into place, using four (customer
supplied) screws or bolts (3).
1
2
3
Safety Precautions
Installation Instructions
L 4035 163 1
L 4545 123 3A
L 4545 123 7D
L 4050 163 10
L 4050 163 1
L 4545 123 3B
L 4035 163 8
L 4050 163 X
L 4035 162 2
L 4035 A 163 5
L 4050 163 8
L 4545 123 X
L 4050 162 2
L 4050 A 163 5
L 4050 163 9
L 4000
L 4035 163 3
L 4545 123 7
L 4545 123 9
L 4100
L 4050 163 3
L 4545 123 7A
L 4545 123 9G
L 4500
L 4545 123 3
L 4545 123 7B
L 4035 163 10