Pumptec 207V SERIES User Manual
Page 2
![background image](/manuals/357682/2/background.png)
2
Version 110112
Pumptec Operating Instructions and Parts Manual
PUMP SERIES 205V | 207V
uNPAcKINg
Remove all packing materials. Carefully remove the plunger
pumps from the shipping carton. Inspect for any damage that
may have occurred during transit. Check for any loose, missing
or damaged parts.
The contents includes 1 item: Pumptec pump and motor unit
assembly
SPecIfIcAtIoNS
Maximum specifications refer to individual performance levels.
Maximum performance ratings are maximums and may be
conditional on other factors. Consult Troubleshooting section
when operating near any performance maximum. Refer to
individual pump data sheets for complete specifications, parts
list and exploded view.
Model 205V – Simple, Single Plunger Pump
MAx PreSSure
. . . . . . . . . . . . . . . .
to 800 PSI
OPEN FLOw
. . . . . . . . . . . . . . . . . .
to 2.5 gPM
SEALS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V-RiNg
O-RiNgS
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
BuNA
iNLEt PORtS (2 or 3)
. . . . . . . . . . .
3/8” f NPt
DiSCHARgE PORtS (2 or 3)
. . . . .
3/8” f NPt
mAx FLuiD tEmP
. . . . . . . . . . . . . . . .
tO 140˚F
RPm (mAx)
. . . . . . . . . . . . . . . . . . . . . . . . . . .
2000
mAtERiALS OF CONStRuCtiON
BODy
. . . . . . . . . . . .
ANODizED ALumiNum
PLuNgER
. . . . . . . . . . . . . . . . . . . . . . . . . . .
304 SS
VALVES
. . . . . . . . . . . . . . . . . .
StAiNLESS StEEL
fASteNerS
. . . . . . . . . . . . . .
StAiNLESS StEEL
Model 207V – Simple, Single Plunger Pump
MAx PreSSure
. . . . . . . . . . . . . . . .
to 800 PSI
OPEN FLOw
. . . . . . . . . . . . . . . . . .
to 1.4 gPM
SEALS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
V-RiNg
O-RiNgS
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
BuNA
iNLEt PORtS (2)
. . . . . . . . . . . . . . . .
3/8” f NPt
DiSCHARgE PORtS (2) . . . . . . . 3/8” f NPt
mAx FLuiD tEmP
. . . . . . . . . . . . . . . .
tO 140˚F
RPm (mAx)
. . . . . . . . . . . . . . . . . . . . . . . . . . .
2000
mAtERiALS OF CONStRuCtiON
BODy
. . . . . . . . . . . .
ANODizED ALumiNum
PLuNgER
. . . . . . . . . . . . . . . . . . . . . . . . . . .
305 SS
VALVES
. . . . . . . . . . . . . . . . . .
StAiNLESS StEEL
fASteNerS
. . . . . . . . . . . . . .
StAiNLESS StEEL
gENERAL SAFEty iNFORmAtiON
Please read this manual before installing or operating pump
to provide safe operation and prevent equipment problems.
Observe the following symbols and definitions.
Note:
Indicates important instructions which are not related
to hazards.
IMPortANt:
Indicates factors concerned with assembly,
installation, operation, or maintenance which could result in
damage to the machine or equipment if ignored.
cAutIoN!
Warns about hazards that MAY cause
minor personal injury or property damage if ignored.
WArNINg!
Warns about hazards that COULD cause
serious personal injury, death or major property damage if
ignored.
DANgER!
Warns about hazards that WILL cause
serious person injury, death or major property damage if
ignored.
___________________________________________
PLEASE READ, SAVE AND REFER tO SAFEty
iNStRuCtiONS BELOw:
cAutIoN!
Pumps build up heat and pressure during
operation. Allow time for pumps to cool before handling or
servicing. Only qualified personnel should install, operate, and
repair pump.
IMPortANt:
For pumping liquids other than water, contact
your supplier.
DANgER!
Do not pump hazardous materials
(flammable, caustic, etc.), unless the pump is specifically
designed and designated to handle them.
WArNINg!
To reduce risk of electric shock, always
disconnect pump from power source before handling or
servicing.
WArNINg!
Any wiring of pumps should be performed
by a qualified electrician.
cAutIoN!
These pumps are not intended to be
submersed.