REMOVING/REPLAClNG THE NEEDLE AND HANDLE (Illustration A):
1. Unscrew the handle and loosen the Locknut #23 by turning counterclockwise. Depress the Trigger #12 and hold in Down position while
removing or inserting the needle. This assures the needle moves freely through the trigger. Gently remove the needle, rotating if necessary,
Do NOT force out!
2. A loose needle can cause sputtering if there is any air leakage around the needle and Packing & Packing Nut #7. If there is no noticeable
drag on the needle by the packing then tighten nut of the Packing & Packing Nut Assembly #7.
3. Inspect the condition of the needle. If it is bent or misshapen in any way, replace it with a new needle. A bent needle can damage or split the
Tip #5 causing bubbles or a rough spray pattern.
4. Hold trigger in DOWN position, insert the new needle into the Rocker Assembly #17. Gently push needle through, rotating if necessary,
push gently forward until the needle stops in the front of the tip.
5. Release trigger and tighten locknut by turning clockwise.
REPLACING THE TRIGGER (Illustration B):
If the Trigger #12 is removed, it must be replaced inside the airbrush shell, before the Rocker Assembly #17 and needle are re-inserted.
1. Hold trigger so the opening in the lever is in-line with the opening in the end of the airbrush shell (see B - END VIEW).
2. Insert trigger straight DOWN through the opening in the top of the airbrush shell (see B - TOP VIEW).
3. Once the trigger has been inserted into the valve casing, you will be able to press down on the trigger and it will return to the up position
when released. Proceed to replace rocker assembly and balance of parts as above. The needle when inserted will prevent the removal of
the trigger.
REPLACING THE TIP:
1. Remove handle, loosen Locknut #23 and withdraw needle about one inch (1").
2. Un-screw the Aircap Body #4 and remove. The Tip #5 can now be easily removed by hand. If stuck in shell tap lightly with wrench.
3. Place a new tip into position and tighten aircap body to shell with a wrench. Push needle forward until it seats fully forward in tip and tighten
locknut.
ADJUSTING WORN PACKING WASHER:
1. If PTFE Packing #7 becomes worn or loose it must be tightened or replaced.
2. Tighten the Packing Nut of the assembly #7 with small screwdriver. To reach packing, guts of airbrush must be removed.
3. Replace needle and make sure packing nut is not too tight. A slight resistance to movement is needed when needle is passed through.
4. Completely re-assemble guts of airbrush.
CLEANING THE AIRBRUSH:
1. Paint passes from the cup connection forward so the trigger area back will most likely not need cleaning.
2. In between color changes or before storing the airbrush attach cup with appropriate cleaner and spray into sink until it runs clear.
3. Remove needle and wipe clean then replace.
4. If paint has dried for a time you can remove the front tip, aircap and aircap body for soaking or soak just the front of the airbrush in cleaner.
5. Use cleaner for the material you are spraying. Keep trigger area dry if soaking.
PERSONAL SETTINGS:
Needle Adjustment Sleeve- Used to increase or decrease spring tension for the trigger pull back. Thread into the shell until the trigger
stroke feels comfortable. Threading in until it stops can cause the trigger to jam.
TROUBLESHOOTING:
Bubbling in cup
1. VB Aircap Body #4 needs to be wrench tightened
Skipping or Spitting:
1. Paint too thick
-Reduce with thinner
2. Tip not seated
-Tighten VB aircap body with wrench
3. Tip split or damaged Needle
-Replace tip or needle
4. Needle or tip dirty
-Clean and replace
5. Air pressure too low
-Increase pressure or thin paint further (need 20 or more PSI to spray most paints)
Airbrush Not Spraying:
1. Clogged tip
-Remove tip and clean
2. Needle not moving
-Tighten needle locknut
3. Loose VB aircap body
-Wrench tighten
4. Low air pressure
-Increase pressure (need 20 or more PSI to spray most paints)
5. Bottle vent hole plugged
-Use needle or pin to clear air hole
Sprays double line or heavy to one side:
1. Split tip or bent needle
- Replace
2. Dirty tip or needle
- Remove and clean
3. Tip not centered in aircap
- Remove head and clean airbrush seat and tip seat then reassemble. Use wrench for aircap body
Jammed trigger or poor trigger motion:
1. Adjust Needle Adj. Sleeve
- Screw or unscrew the sleeve to lessen or increase tension on trigger motion
2. Paint leaking to trigger area
- Remove guts of airbrush and slightly tighten packing or replace if needed
3. Lubricate needle and trigger
- Apply lubricant to needle shaft and trigger slot area