G1100 – NOCO Genius G1100 User Manual
Page 6
9
8
G1100
geniuschargers.com
BATTERY SPECS
The G1100 is suitable for charging all types of 6V &12V lead-acid batteries,
including Wet (Flooded), Gel, MF (Maintenance-Free) and AGM (Absorption
Glass Mat) batteries. The G1100 is suitable for charging batteries sized from
2.2 to 40Ah. The battery charger can also maintain all battery sizes.
CHARGE MODES
The G1100 is equipped with four (4) charging modes: 6V NORM, 6V COLD/
AGM, 12V NORM and 12V COLD/AGM. Before selecting a charge mode, it is
important to understand the differences and the purpose of each mode. The
charge modes are explained below:
The “normal” (“NORM”) charge mode is for charging
Wet Cell, Maintenance-Free and Gel Cell batteries. If
you are unsure of the chemistry of your battery, use
the NORM charge mode. When selected, a Red LED
will illuminate.
The COLD/AGM charge mode is for charging
batteries in cold weather and AGM (also known as
“spiral wound”) batteries. If a battery’s (Wet, Gel, MF
or AGM) temperature is below 32
o
F (0
o
C), use the
COLD/AGM charge mode. If you are unsure of the
chemistry of your battery, DO NOT use this charge
mode, and use the NORM charge mode instead.
When selected, a Blue LED will illuminate.
The “normal” (“NORM”) charge mode is for charging
12V Wet Cell, Maintenance-Free and Gel Cell
batteries. If you are unsure of the chemistry of your
battery, use the NORM charge mode. When selected,
a Red LED will illuminate.
6V NORM
7.2V
2.2-40Ah
1.1A (1100mA)
Red LED
6V COLD/AGM
7.4V
2.2-40Ah
1.1A (1100mA)
Blue LED
12V NORM
14.4V
2.2-40Ah
1.1A (1100mA)
Red LED
USING THE G1100
MODE EXPLANATION
The COLD/AGM charge mode is for charging 12V
batteries in cold weather and AGM (also known as
“spiral wound”) batteries. If a battery’s (Wet, Gel, MF
or AGM) temperature is below 32
o
F (0
o
C), use the
COLD/AGM charge mode. If you are unsure of the
chemistry of your battery, DO NOT use this charge
mode, and use the NORM charge mode instead.
When selected, a Blue LED will illuminate.
12V COLD/AGM
14.7V
2.2-40Ah
1.1A (1100mA)
Blue LED
USING THE G1100
WICKED SMART TIP
Amp Hour (Ah) is a rating that measures a battery’s storage capacity.
The Ah rating indicates how much amperage is available in the battery
over a twenty (20) hour period. In order to determine how many
constant Amps the battery can output for 20 hours, divide the Ah rating
by 20. For example, if you have a 100Ah battery, it can deliver 5 Amps
for 20 hours before it is fully discharged (100 / 20 = 5).
Now That’s Smart, Wicked Smart.™
MODE EXPLANATION
CHARGE MODES continued