Cartridge operation/features, Helmet care and maintenance, Shade guide settings – Lincoln Electric IM10095 VIKING 3350 SERIES AUTO-DARKENING HELMETS User Manual
Page 8
CARTRIDGE OPERATION/FEATURES
Variable Shade Control
The shade can be adjusted from shade 6 to 9 and 9 to 13 based upon welding
process or application (refer to shade selection chart on page 6). Shade is
adjusted by setting the shade range switch to the proper range, then use the
shade dual scale dial to set the desired shade. The shade range switch and dual
scale dail are located on the ADF cartridge as shown below.
Test
Press and hold test to preview shade selection before welding. When released
the viewing window will automatically return to the light state (3.5 Shade).
Sensitivity Knob
Adjust the light sensitivity by turning the SENSITIVITY knob to the left or right as
shown in the figure below. Turning the knob all the way to the left, the HIGH set-
ting, is typically selected for normal use. When helmet is used in the presence of
excess ambient light or with another welding machine close by, improved helmet
performance can be obtained with a lower setting by turning the knob to the right to
reduce the sensitivity. Grind mode can be selected by rotating the sensitivity knob
all the way to the right until an audible click is heard.
Grind mode is intended for grinding only not for welding.
Delay Knob
This control is designed to protect the
welder's eyes from the strong resid-
ual rays after welding. Changing the
DELAY knob will vary the dark to light
time between 0.1 second (SHORT) to
1.0 second (LONG). LONG setting is
recommended for welding arc has
ceased and for situations where the
filter may be temporarily blocked from
seeing the welding arc.
Power
This ADF cartridge is powered by a
replaceable battery and solar power.
The battery is located at the bottom
corner of the ADF cartridge. Replace
battery when LOW BATTERY light
is lit. See the specification chart on
page 3 for type of battery required.
5
SHADE RANGE SWITCH
DUAL SCALE DIAL
*
DELAY TIME
SHADE 6-9
LONG
SHORT
SENSITIVITY
HIGH
LOW
GRIND
SHADE
9(6)
13(9)
12(
8)
11(7)
10
(6.
5)
SHADE 9-13
LOW
BATTERY
TEST
3350 SERIES ADF
S27978-65
LABS
CAN/CSA Z94.3
TMZ87W4/6-13
4/6-13 1/2/1/1/379 CE
CR2450
HELMET CARE AND MAINTENANCE
Cleaning: Clean helmet by wiping with a soft cloth. Clean cartridge surfaces
regularly. Do not use strong cleaning solutions. Clean sensors and solar cells
with soapy water solution and a clean cloth and wipe dry with a lint-free cloth.
Do NOT submerge shade cartridge in water or other solution.
Storage: Store in a clean, dry location.
SHADE GUIDE SETTINGS
If your helmet does not include any one of the shades referenced above, it is
recommended you use the next darker shade.
6
NT 1
GUIDE FOR SHADE NUMBERS
OPERATION
ELECTRODE SIZE
ARC
MINIMUM
SUGGESTED(1)
1/32 in. (mm)
CURRENT (A)
PROTECTIVE
SHADE NO.
SHADE
(COMFORT)
Shielded metal arc
Less than 3 (2.5)
Less than 60
7
–
welding
3-5 (2.5–4)
60-160
8
10
5-8 (4–6.4)
160-250
10
12
More than 8 (6.4)
250-550
11
14
Gas metal arc
Less than 60
7
–
welding and flux
60-160
10
11
cored arc welding
160-250
10
12
250-500
10
14
Gas tungsten arc
Less than 50
8
10
welding
50-150
8
12
150-500
10
14
Air carbon
(Light)
Less than 500
10
12
Arc cutting
(Heavy)
500-1000
11
14
Plasma arc welding
Less than 20
6
6 to 8
20-100
8
10
100-400
10
12
400-800
11
14
Plasma arc cutting
(Light)
(2)
(2)
(2)
Less than 300
8
9
(Medium)
300-400
9
12
(Heavy)
400-800
10
14
Torch brazing
–
–
3 or 4
Torch soldering
–
–
2
Carbon arc welding
–
–
14
PLATE THICKNESS
in.
mm
Gas welding
Light
Under 1/8
Under 3.2
4 or 5
Medium
1/8 to 1/2
3.2 to 12.7
5 or 6
Heavy
Over 1/2
Over 12.7
6 or 8
Oxygen cutting
Light
Under 1
Under 25
3 or 4
Medium
1 to 6
25 to 150
4 or 5
Heavy
Over 6
Over 150
5 or 6
(1)
As a rule of thumb, start with a shade that is too dark, then go to a lighter shade which gives sufficient view of the weld zone without going
below the minimum. In oxyfuel gas welding or cutting where the torch produces a high yellow light, it is desirable to use a filter lens that absorbs
the yellow or sodium line the visible light of the (spectrum) operation
(2)
These values apply where the actual arc is clearly seen. Experience has shown that lighter filters may be used when the arc is hidden by the
workpiece.
.
Data from ANSI Z49.1-2005