Vanguard CBCT User Manual
Page 6
CBCT USER’S MANUAL
REV 1
3
1.2 Technical
Specifications
Table 1. CBCT Technical Specifications
TYPE Programmable DC Power Supply
PHYSICAL SPECIFICATIONS 19”W x 7”H x 15”D, (48 cm x 17 cm x 38 cm); Weight: 25 lbs (11.3 kg)
INPUT VOLTAGE
20 – 300 Vdc, 20A fuse
OUTPUT VOLTAGE 5% – 95% of input voltage with 2% regulation at max current (up to 80A)
OUTPUT VOLTAGE CHANNELS One continuous and one pulse DC output
OUTPUT VOLTAGE
PROTECTION
Shutdown if current exceeds 80A or if current drawing time exceeds 500
ms @ 80A
VOLT METER RANGE Input/output meters, 0 – 300 Vdc; Accuracy: 1% of reading, ±0.2V
TIMER DISPLAY RANGE 0.0000 – 999.999 seconds; Accuracy: 0.1 ms, ±1 digit
TIMER START INPUT Internal (coil initiation), wet-contact input (10 c 240 Vac/dc), or dry-contact
input (1 – 200 ohms)
TIMER STOP INPUT Wet-contact (10 – 240 Vac/dc) or dry-contact (1 – 200 ohms)
DISPLAY Back-lit LCD screen (20 characters by 4 lines); viewable in both bright
sunlight and low-light levels
SAFETY Designed to meet UL 6101A-1 and CAN/CSA C22.2 No 1010.1-92
standards
ENVIRONMENT Operating: -10°C to 50°C (+15°F to +122°F); Storage: -30°C to70°C (-22°F
to +158°F)
CABLES Three 6-foot (#10 AWG) DC cable sets, Two 10-foot timer cable sets, One
ground cable, one cable bag
OPTIONS Transportation case
WARRANTY One year on parts and labor
NOTE
The above specifications are valid at nominal operating voltage and at a
temperature of 25
°C (77°F). Specifications may change without prior notice.