SERIES OPERATION
&
CARE MANUAL
• 6
1.
An identification tag is permanently mounted on
the cabinet.
2.
Plug cabinet into a properly grounded receptacle
ONLY, positioning the unit so the power supply
cord is easily accessible in case of an emergency.
3.
If necessary, a proper receptacle or outlet
configuration as required for this unit,
must be installed by a licensed electrician
in accordance with applicable, local electrical codes.
NOTE:
230V units:
To prevent an electrical shock hazard between
the appliance and other appliances or metal
parts in close vicinity, an equalization-bonding
stud is provided. An equalization bonding lead
must be connected to this stud and the other
appliances / metal parts to provide sufficient
protection against potential difference. The
terminal is marked with the following symbol.
The appliance must be connected to an
electrical circuit that is protected by an
external GFCI outlet.
D A N G E R
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.
D A N G E R
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in accordance with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.
D A N G E R
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
ELECTRICAL
• 1000-BQ2/192
VOLTAGE
PHASECYCLE
/
HZ
AMPS
kW
CORD
&
PLUG INCLUDED
120 (
AGCY
)
1
60
NEMA
L5-20
P
POWER SWITCH IN LOW POSITION
16.0
1.9
20A- 125V
PLUG
POWER SWITCH IN HIGH POSITION
24.0
MAX
3.0
NEMA
L5-30
P
30A - 125
V PLUG
208-240 (
AGCY
) 1
60
12.5
3.0
NEMA
6-15
P
at 208
1
60
11.8
2.5
15A - 250V
PLUG
at 240
1
60
13.6
3.3
230 (
AGCY
)
1
50
13.0
3.0
CEE
7/7
220-230V
PLUG
ELECTRICAL
• 1000-BQ2/128
VOLTAGE
PHASECYCLE
/
HZ
AMPS
kW
CORD
&
PLUG INCLUDED
120 (
AGCY
)
1
60
16.7
2.0
NEMA
5-20
P
20A- 125V
PLUG
208-240 (
AGCY
)
1
60
8.7
2.0
NEMA
6-15
P
208
1
60
7.7
1.6
15A - 250V
PLUG
240
1
60
8.9
2.1
230 (
AGCY
)
1 50/60
8.4
2.0
CEE
7/7
220-230V
PLUG
ELECTRICAL
• 1000-BQ2/96
VOLTAGE
PHASECYCLE
/
HZ
AMPS
kW
CORD
&
PLUG INCLUDED
120 (
AGCY
)
1
60
12.8
1.6
NEMA
5-15
P
15A- 125V
PLUG
208-240 (
AGCY
)
1
60
6.7
1.6
NEMA
6-15
P
at 208
1
60
5.9
1.2
15A - 250V
PLUG
at 240
1
60
6.7
1.6
230 (
AGCY
)
1 50/60
6.5
1.5
CEE
7/7
220-230V
PLUG
E L E C T R I C A L C O N N E C T I O N
I N S T A L L A T I O N
Wire diagrams are located inside the top of the unit.