Southern Folger 8050L PNEUMATIC LOCKING SYSTEM User Manual

8050l pneumatic locking system, Function, Technical data

background image

FOR MORE INFORMATION, PLEASE CALL 210-533-1231

Revised 3/09

8050L PNEUMATIC
LOCKING SYSTEM

The 8050L Locking System offers
complete selective electric
operation of sliding doors in a line
or group from a remote control
station. Doors are operated by
pneumatic cylinders over each
door. This system also provides
emergency pneumatic unlocking
from a remote location. Doors are
locked at top and bottom in both
the open and closed positions by
means of a concealed vertical lock
bar at the rear jamb of each door.
The vertical lock bar is deadlocked
at a third locking point inside the
horizontal cover box above the
door. Standard clear door opening
widths are from 2'4" to 3'2".

FUNCTION:

ELECTRIC - A remote switch
activates pneumatic cylinders
which raise a vertical lock bar and
propel the door open or closed.
Individual lamp indicators on the
control panel show locked/unlocked
condition. A single switch can
provide group unlocking.

MECHANICAL - In the absence of
pneumatic or electrical power,
doors may be individually unlocked
with a manual release tool. Door
movement is by hand and door will
relock in either fully open or closed
position.

EMERGENCY GANG RELEASE -
In an emergency, all doors in a cell
line may be simultaneously
unlocked from a remote
location using a pneumatic
release system. While in
emergency release mode, doors
will not relock in any position.

8050L

PNEUMATIC

LOCKING SYSTEM

TECHNICAL DATA:

• COVER BOX:

1' 0-3/4" H x 7-1/2" D

• COVER BOX MATERIAL:

7 gauge steel plate

• HINGED PANEL:

10 gauge steel

• DOOR ROLLERS:

3" diameter, machined
steel with sealed bearings

• VERTICAL LOCK BAR

DIMENSIONS:
5/8" SQ by full height
of door

• FINISH: Prime paint
• DOOR HANGER:

7 gauge steel plate

• ELECTRICAL: 24 VDC

Minimum of five 24 volt
conductors are required between
the control point and the door,
except for those models
having the letter “K”
(keyswitch) in the suffix.
Keyswitch models require
minimum six conductors.

• AIR REQUIREMENTS:

Air consumption varies with
door size at 80 PSIG.

L O C K I N G S Y S T E M S

FOR GROUPS OF
SLIDING CELL DOORS

Maximum security.

C9