3150lx.b electric locking system, Standard features, Optional features – Southern Folger 3150LX.b ELECTRIC LOCKING SYSTEMS User Manual
Page 2

P.O. BOX 2021 • SAN ANTONIO, TX • 78297 • 210-533-1231 • FAX: 210-533-2211
Revised
7/12
L O C K I N G S Y S T E M S
FOR GROUPS OF
SLIDING CELL DOORS
Maximum security.
STANDARD FEATURES:
• Bottom door guide
• Door hanger
• Mechanical release cabinet
• Sloped-front cover box
• Hinged cover panel for maintenance access
• Vertical lock bar assembly
• ASTM F1643 Certified
Horizontal and Vertical Impact Test-Grade 1
• Prime paint finish
OPTIONAL FEATURES:
PILASTER RELEASE – (In lieu of mechanical
release cabinet.) Hip-high paracentric keyed
mechanical release mounted in a full-height pilaster
adjacent to the receiving jamb.
Specify “3150LX.bP-1” keyed one side.
ELECTRIC KEYSWITCH – Paracentric or mogul
keyed local electric control switch mounted below
mechanical release mechanism in pilaster.
Specify “3150LX.bPK-1” for paracentric keyed one side.
Specify “3150LX.bPKM-1” for mogul keyed one side.
HOT DIP GALVANIZED FINISH - Available for external
applications with lift-off cover panel only. Not available
with standard hinged cover panel. Specify ”G” when
ordering. Example: 3150LX.b P-1G
REMOTE PANEL LOCK SYSTEM - Remote panel
option is available with lift-off cover panel only. Not
available with standard hinged cover panel. Specify
“RP” when ordering. Example: 3150LX.bRP
FACTORY WIRED CONTROL CABLE
Specify “3150LX.bWC.”
NOTE: Cover box minimum length =
(7"overtravel) + (2 x clear opening) + 9".
For doors exceeding 300 lbs. and/or greater
than 3’-2” clear opening, contact factory.
THREE HOUR FIRE DOOR RATING
AVAILABLE. Standard cover box calculation
does not apply to fire rated door.
3150LX.b ELECTRIC
LOCKING SYSTEM
3150LX.b Shown
Note: Other system configurations and details are available.
Call Customer Service for more information.
B22
DETAIL B – VERTICAL LOCK JAMB BAR
3150LX.b SLIDING DOOR SYSTEM
DETAIL C – RECEIVER
DETAIL D – BOTTOM DOOR GUIDE SECTION
COVER BOX SECTION
7-1/2" deep x 1'-3/4" tall
cover box field welded 1" on 8"
top and bottom.
RECEIVER JAMB SECTION
Flush receiver jamb allows frame
opening and clear opening to
be the same.
DETAIL A – SLOPED BOX