Standard Features_______

s

Motor voltage – 120 VAC.

s

Rack and pinion gear drive.

s

Heavy duty construction – 3B.2

devices are built for the rigors of
maximum security applications.

s

Tamper-resistance – Openings in

housings are baffled to preclude
inmate tampering.

s

Selective operation – Single or

groups of doors may be
simultaneously opened, or closed and
locked.

s

Sloped-top housing – Resists hiding

of contraband. Flat-top housing is
provided where the device must
install close to the ceiling.

s

Automatic locking – When fully

closed, top and bottom locking points
on the rear of each door are forced
down into the deadlocked position.

s

Indication switch – Monitors the
locked condition of both locking
points.

s

Gang release – From mechanical

release cabinet.

s

Self-contained – A continuous,

surface-mounted housing contains the
drive and mechanical release
mechanisms and wiring.

s

Full length wire tray – Simplifies

routing of electrical wire/harnesses.
Runs the full length of the housing.

s

Terminal strips – All internal

components are pre-wired to a
terminal strip. The strip is also used
for ease of field wiring.

Optional Features________

s

Mechanical release cabinet – See
page D21-22.

s

Key switches – May be added in
columns or nearby for local electric
control.

s

Electrical/mechanical controls –
Electrical switches may be specified to
provide control of each door in
addition to mechanical function.
These switches may be built into the
same cabinet as the mechanical
levers, or located at a remote console,
as needs dictate. The following switch
functions are available:
Three-position operating switches –
(OPEN-GROUP-CLOSE).
Group switch – Provides group
control (OPEN-OFF-CLOSE).
Power cut-off switch – Cuts off
electrical current to controls.
Indication Lamps – Red and green
indicator lamps may be installed in
conjunction with switches to show
locked, closed, or open status of each
door. When used, the indication is as
follows:
Red – Unlocked, moving or stopped
in mid-travel.
Green - Locked closed.

s

Custom graphic consoles – In many
cases, it may be desirable to separate
electric controls from the mechanical
release cabinet located near the cells.
For larger installations, or those with
particular needs, custom-built control
consoles may be easily provided with
floor plan graphics screened on the
control panel, and an array of
specialized features.

s

Cell line cable – For applications
using a series of locking devices, a
cell line cable may be specified to
interconnect to terminal strips in the
mechanical control/release cabinet.
Simplifies routing of wire and saves
installation cost and time.

s

G90 galvanized finish available.

FOLGER ADAM LOCKING DEVICES

Drive:

Rack and Pinion

Release:

Individual

and/or Gang

Security
Level:

Maximum

3B.2 SLIDING DOOR