LockeyUSA TB-LINX Kit User Manual
Tb-linx kit instructions
![background image](/manuals/351684/1/background.png)
The TB-LINX Kit is intended to adapt your TB200/400/600
or TB250+/450+/650+ Hydraulic Gate Closer to fence posts
3-inches or smaller. The TB-LINX kit comes with a 3” U-
Bolt to fit to a 2 7/8” post.
If the post is smaller than 3-inches, a smaller U-Bolt must
be used to match the post size.
IMPORTANT:
TB200/400/600 and TB250+/450+/650+ Gate Closers will
not work with Bulldog Style hinges. You MUST use a
center pin/pivot type hinges or Male/Female style with
center pivot pin.
TO INSTALL:
1. Mount the Triangular Mounting Bracket to the flat-
side of the Post-Mount Collar using the two (2) 1/4” x
1” bolts and securing with two (2) 1/4" Lock Nuts.
2. Place collar to the OPEN side of POST and attach with
3 x 4 ½” U-BOLT and secure with two 3/8” Lock Nuts.
The gate must swing towards the Triangular Bracket
and the Triangular Bracket should be on a 90 degree
angle from gate.
3. You are now ready to mount the Gate Closer. Use
the 2 self-tapping screws to fit Gate Bracket to gate.
(REFER TO GATE CLOSER INSTRUCTIONS)
IMPORTANT: BEFORE INSTALLATION OF THE CLOSER IT IS IMPORTANT TO MEASURE THE DISTANCE FROM THE TRIANGULAR
BRACKET TO GATE BRACKET IN THE 90-DEGREE OPEN POSITION. THE DISTANCE MUST NOT BE LESS THAN 22”. IF LESS THAN
22”, THE GATE CLOSER MAY HYPER-COMPRESS AND VOID THE WARRANTY.
IN MOST CASES, HOLES 3 & 4 ON THE TRIANGULAR BRACKET (HOLES FURTHEST FROM THE POST), WILL NOT CREATE
SUFFICIENT DISTANCE (22”) BETWEEN THE TRIANGULAR BRACKET AND GATE BRACKET.
Part Name
Qty.
Triangular Mounting Bracket (included w/ Gate Closer)
1
Gate Bracket (included w/ Gate Closer)
1
Post-Mount Collar
1
U-Bolt – 3 x 4 ½
1
Lock-Nuts – 3/8
2
Lock-Nuts – 1/4
2
Bolts 1/4 x 1
2
Self-Tapping Screws
2
TB-LINX Kit
Instructions